Titanium Tube Eddy Current Flaw Detector

The titanium tube eddy current flaw detector induces eddy currents on the surface of titanium tubes through an alternating magnetic field and detects changes in the eddy currents to identify defects. It is used to detect surface cracks, corrosion, and other flaws in titanium tubes, ensuring material integrity in aerospace and chemical pipeline manufacturing.
Selection
When selecting, consider matching the titanium tube specifications with the probe size, set the frequency range according to the testing standards, account for the impact of environmental temperature on equipment stability, ensure that defect recognition accuracy meets process requirements, and ensure that the operation interface aligns with the usage habits of personnel.

Terms

Instruments

With a wide frequency range of 64Hz-2MHz, it can detect longitudinal crazing and transverse defects, adapts to a variety of Probe types, supports automatic phase analysis and zero correction functions, and is suitable for high-speed inspection environments.

$ 7335.00

Frequency range 50Hz~ 12MHz, gain 0~ 90dB continuously adjustable, with relatively independent test channels and a variety of Display modes.

$ 8949.00

Using 64Hz-2MHz broadband range, it can detect vertical crazing and horizontal defects, with automatic zero correction system and sound and light alarm function, and supports a variety of Probe adaptations.

$ 10401.00

Using eddy Current thickness measurement principle, Measurement range 0-1000μm, resolution 0.1μm, minimum measurable convex curvature 3mm, with automatic shutdown and low voltage prompt function.

$ 267.00

Using eddy Current Measurement principle, Measurement range 0~ 1250μm, with continuous single double Measurement mode, metal shell anti-interference, support automatic statistics and storage of 1560 measured values.

$ 344.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 500um, resolution 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support single and continuous Measurement mode.

$ 275.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-2000μm, resolution up to 0.1μm, with automatic identification of substrate function and Data storage ability, support surface measurement minimum convex 1.5mm.

$ 419.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, resolution up to 0.1μm, equipped with wear-resistant hard metal probe and spring guide sleeve Probe, support automatic memory calibrating and RS232C communication.

$ 354.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-3000μm, accuracy +/- 3%, automatically identify the matrix material, no need to calibrate only zero, easy to carry and lightweight.

$ 787.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-2000μm, resolution up to 0.1μm, with automatic matrix recognition and 99 sets of Data storage statistical functions, support surface and minimum area measurement.

$ 592.00

Using magnetic Induction and eddy current double thickness measurement method, Measurement range 0-1250μm, error +/- 3%, automatic identification of iron and non-iron matrix, with statistical function and undervoltage indication, easy to operate.

$ 180.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1500 μm, with temperature compensation function, support continuous fast and High Accuracy Measurement mode, can store 500 sets of data and automatically filtrate outliers.

$ 264.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, error +/- 3%, support Bluetooth transmission and automatic identification of matrix material, suitable for one-handed operation.

$ 564.00

Measurement range of 0-1250 μm using eddy Current principle, single continuous dual mode and large Probe design, support Automatic calibration matrix recognition, error of only +/- 3% resolution up to 0.1 μm.

$ 320.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 2000µm, error +/- 1~ 3%, with automatic identification of matrix material and memory Adjustment, support split Probe to enhance mobility.

$ 338.00