Liquid ammonia gas Detector

Liquid ammonia gas detectors measure the concentration of ammonia in the air using electrochemical sensors. When ammonia molecules react with the sensing electrode, they generate an electrical current signal, which is then converted into a concentration reading by the circuit. These detectors are used in places such as cold storage facilities and chemical plants to monitor ammonia leaks and ensure personnel safety.
Selection
When selecting, ensure the detection range covers the target concentration. Electrochemical sensors are suitable for routine environments, while infrared sensors are ideal for high-humidity or corrosive environments. Check the explosion-proof certification rating, consider response time and calibration intervals, and ensure the data logging function meets the usage requirements.

Terms

Standards

Instruments

Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.

$ 110.00

250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.

$ 127.00

Designed for Ammonia Gas Sensitive Compound ElectRode, it provides a stable reference potential to ensure accurate measurement. The Encasement specification is 250ml, which is suitable for long-term monitoring applications.

$ 143.00

ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.

$ 135.00

Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.

$ 328.00

The filling liquid capacity of 30mL, the use of PTFE bottles, Dimension 65mm high × 30mm diaMeter, weight of only 20g, suitable for the maintenance of Ammonia Gas sensing electRode.

$ 135.00

ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, copper ion type, capacity 480 ml, to ensure ElectRode performance stability and measurement accuracy.

$ 135.00

ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, providing bromine ion type and 480mL capacity to ensure stable ElectRode performance.

$ 135.00

Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.

$ 1806.00

Electrochemical sensor, Response Time ≤ 20 seconds, range 0-100ppm, resolution 0.1ppm, waterproof, dustproof and explosion-proof design, support sound and light vibration triple alarm and Sensor fault self-check function.

$ 202.00

Using 8-bit microcontroller, Response Time is less than 30 seconds, with IP65 Protection Rating and sound and light vibration alarm function, support 1000 sets of alarm record storage.

$ 235.00

The MCU chip is used to achieve low power consumption operation, the detection error is ≤ +/- 3% F. S, the Response Time is ≤ 30 seconds, and it supports a variety of signal output and remote alarm functions to meet the needs of complex industrial applications.

$ 267.00

Pump suction sampling, Response Time T90 ≤ 20 seconds, detection accuracy ≤ +/- 3%, equipped with dust Filter, suitable for harsh environments, support Data storage 120000 groups.

$ 507.00

Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds. With Intrinsic Safety (IS) design, support RS485 and 4-20mA dual output, equipped with 2.5 inch color screen display real-time concentration, Temperature Humidity paraMeters.

$ 630.00

Electrochemical sensor for rapid Response, detection accuracy of +/- 2% F. S, with Intrinsic Safety (IS) design and a variety of signal output interfaces, support remote monitoring and data transmission, adapt to -30~ 50 ℃ working environment.

$ 888.00

Articles

Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Effect of Platform Temperature on Surface Drying Time of Waterborne Polyurethane Coatings in Heated Automatic Film Applicators
This study investigates the influence of the platform temperature of a heated automatic film applicator on the surface drying time of waterborne polyurethane coatings. The experiments reveal that as the platform temperature increases, the surface drying time of the coating significantly decreases, showing a negative correlation between the two.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.