Adopt unique equilibrate temperature control method to achieve High Accuracy Temperature Control, Temperature Uniformity ≤ + 2 ℃, equipped with a large area observation window for real-time observation of sample test status, the studio is made of 304 stainless steel.
Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.
The equilibrate temperature control method is used to achieve +/- 0.5 ℃ Temperature Fluctuation, Temperature Uniformity ≤ + 2 ℃, and the large-area observation window can monitor the sample status in real time to meet the strict environment testing requirements.
High Accuracy Temperature Control with Unique Equilibrate Temperature Control, Temperature Uniformity ≤ + 2 ℃, Large Area Observation Window for Real-time Observation of Sample Test Status, to meet various environmental adaptability testing needs.
Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.
The equilibrate temperature control method is used to achieve Temperature Fluctuation ≤ +/- 0.5 ° C, humidity control range is 30-98% RH, equipped with a large area observation window to observe the sample status in real time, and the studio is made of 304 stainless steel.
Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.
Temperature range -20~ 150 ℃, volume 800L, mirror stainless steel inner wall and automatic adjustment refrigerator operation, to ensure Temperature Uniformity ≤ 2.0 ℃, suitable for high and low temperature cycle test.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and aging test, in line with a number of national standards.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.
80L studio volume with -20~ 150 ℃ wide temperature control, using fully enclosed low noise Compressor and automatic adjustment of refrigeration conditions, Temperature Uniformity ≤ 2.0 ℃ to ensure test stability.
Temperature range -60~ 150 ℃, studio volume 1000L, stainless steel studio and high temperature insulation material, support high and low temperature cycle change test, in line with a number of national standards.
Temperature range -40~ 150 ℃, studio volume 150L, suitable for high temperature and low temperature Reliability test, in line with a number of national standards, aging test and constant temperature test.
Temperature range -70~ 150 ℃, studio volume 80L, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature cycle change test, support aging test and a variety of standard requirements.