Conductivity Detector principle and temperature and humidity compensation technology, measurement accuracy of +/- 0.5%, Response Time of 1 second, integrated design supports on-site rapid detection, suitable for a variety of grain moisture measurement.
Temperature and humidity compensation technology, measurement Precision +/- 0.5%, Response Time less than 1 second, with MAX Maximum hold and automatic shutdown function, optional single and double pin Sensor, easy to quickly detect on site.
Temperature and humidity compensation technology, measurement range 0~ 35%, error accuracy 0.1, Response Time less than 1 second, with MAX Maximum hold and alarm function, portable design weight only 203 grams.
Adopt Temperature and Humidity Compensation Technology to Improve Measurement Precision, Measurement range 4~ 90%, Response Time is only 1 second, Compact size is convenient for on-site rapid detection, Support a variety of data transmission interface customization.
Measurement principle using Conductivity Detector method, Measurement range 8~ 40%, accuracy +/- 0.5%, with automatic compensation function of Temperature and Humidity, Response Time is only 1 second, Portable design weight about 203 grams, suitable for on-site rapid detection.
Temperature range -20~ 150 ℃ and humidity control 30~ 98% R.H., using PID control and solid state relay to ensure stability, multi-layer Glass observation window frost-proof design, support a variety of safety protection functions.
Conductivity Detector principle and temperature and humidity compensation technology, measurement range 5-35%, accuracy +/- 0.5%, Response Time 1 second, integrated design is easy to carry, suitable for on-site rapid detection.
Temperature and humidity compensation technology to improve measurement accuracy, Measurement range 5~ 45%, accuracy +/- 0.5%, Response Time 1 second, portable design weight of only 175 grams, with backlit LCD display and automatic shutdown function.
Conductivity Detector measurement principle, Response Time is only 1 second, with temperature and humidity compensation technology, measurement accuracy +/- 2%, split design is easy to carry on site, support 3 sets of measurement code storage.
Conductivity Detector measurement principle, measurement range 0-80%, resolution 0.1%, Response Time 1 second, with temperature and humidity compensation and backlight display, easy to quickly detect on site.
Temperature and humidity compensation technology to improve measurement Stability, Measurement range 0-84% and accuracy of +/- 0.5%, Response Time less than 1 second, with MAX Maximum hold and alarm function, support custom data transmission interface.
Measurement accuracy is ensured by temperature and humidity compensation technology, Response Time is only 1 second to achieve fast detection, probe Sensor can penetrate deep into the material internal measurement, support error fine-tuning and data transmission functions.
Conductivity Detector Measurement principle, Measurement range 0-50%, Response Time less than 1 second, with temperature and humidity compensation function, split design for quick detection on site.
Temperature range of -40~ 150 ℃ and 20~ 98% Humidity control, anti-condensation design of laminated Glass viewing window, support multi-stage program editing and fast slope control, meet a variety of standard test requirements.
Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.