Acid-Alkali Water Bath

The acid-base water bath uses electric heating to maintain a constant temperature of the water bath medium, leveraging the uniform heat transfer properties of the water bath to provide a stable temperature environment for samples in containers. It is used in laboratories for constant-temperature heating, evaporation, or reaction operations of acid-base solutions, commonly employed in sample pretreatment processes in the chemical and materials industries.
Selection
When selecting, consider that the inner liner material must be resistant to acid and alkali corrosion, typically choosing stainless steel or polytetrafluoroethylene. Determine the inner liner size based on the experimental capacity, and select a digital temperature control system according to the required temperature control accuracy. Pay attention to matching the heating power with the heating rate, and ensure that it is equipped with a dry-burn protection function.

Terms

Standards

Instruments

Microcrystalline Glass panel resistant to strong acid and alkali, low expansion coefficient to ensure high temperature without deformation, the highest Operating temperature 450 ℃, surrounded by 316L stainless steel material comprehensive corrosion resistance.

$ 643.00

Microcrystalline Glass panel is resistant to strong acid and alkali, low expansion coefficient to ensure no deformation at high temperature; Operating temperature 450 ℃, ceramic fiber insulation material is lightweight and efficient, and 316L stainless steel around is corrosion resistant.

$ 612.00

Microcrystalline Glass panel resistant to strong acid and alkali, low expansion coefficient to ensure high temperature without deformation, the highest Operating temperature 450 ℃, 316L stainless steel material comprehensive anti-corrosion, ceramic fiber insulation material lightweight and efficient.

$ 403.00

Using 8.0mmPP polypropylene (PP) plate welding, strong acid and alkali corrosion resistance, surface wind speed 0.4-0 m/sec, noise control below 65dB, the baffle can be disassembled and assembled with repeability to ensure uniform gas discharge.

$ 2187.00

The PHY Glass membrane is used to withstand strong acid and alkali corrosion, and the membrane Impedance is less than 500MΩ to ensure the measurement Stability; the porous PTFE liquid complex and 3M KCl gel electrolysis solution are designed to improve the anti-pollution performance, suitable for 0-130 ℃ high temperature environment.

$ 296.00

Using 525nm LED Illuminant, Measurement range 0.0-30 ppm, accuracy +/- 1.0ppm, based on amino acid method to achieve high Sensitivity phosphoric acid salt detection, suitable for a variety of water quality environments.

$ 215.00

Using stainless steel material acid and alkali resistance, wet film thickness 25μm accuracy +/- 2μm, suitable for flat substrate coating, in line with ASTM multiple test standards.

$ 1406.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Using stainless steel material acid and alkali, wet film thickness 50μm accuracy +/- 2μm, suitable for flat and solid substrate coating different pRoducts, surface polishing.

$ 1406.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

Using transparent carbonic acid ester Bath design, the highest Operating temperature is 100 ℃, equipped with 13L volume Tank body. With low liquid level protection and hardware over-temperature protection function, support Pt100 temperature sensor calibrated, pump Flow rate up to 12L/min, provide multi-stage program control and a variety of safe operation modes.

$ 751.00

It adopts transparent carbonic acid ester Bath design, with a volume of 6L, equipped with pressure/suction pump and Pt100 temperature sensor, with low liquid level protection and hardware over-temperature protection functions, and supports external circulation temperature control.

$ 1519.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Articles

Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Key points for measuring the pH of water-based ink with a pH meter
This article introduces the key steps for measuring the acidity or alkalinity of water-based inks using a pH meter.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
Constant Temperature Water Bath Controls the Temperature Sensitivity of Resin Viscosity
The constant temperature water bath can provide a stable temperature environment for studying the characteristics of resin viscosity as it changes with temperature.