Measurement range 0-100 ° SR, equipped with a special measuringflask to directly display the Freeness/Schopper-Riegler value, without conversion, the test water temperature is controlled at 20 +/- 0.5 ° C to ensure accurate and reliable detection results.
Measurement range 0~ 100 ° SR, cone rising speed 100 +/- 10mm/s, suitable for all kinds of Pulp suspensions, can use raw materials economically and end the Refining process in time, simple and reliable operation.
Measurement range 1~ 100 ° SR, sealing cone rising speed 100 +/- 10mm/s, Pulp suspension filtration rate was determined according to Schopper-Riegler method.
Manual compression sealing vertebral body design, three-legged leveling mechanism to ensure sealing, Measurement range 0~ 100 ° SR, cone rising speed 100 +/- 10mm/s, overflow port discharge time 149 +/- 1s.
Measurement range 0~ 100 ° SR, overflow discharge time 149 +/- 1s, using national standard design, can accurately detect Pulp suspension filtration rate.
Measurement range 0~ 100 ° SR, overflow discharge time 149 +/- 1 seconds, cone rising speed 100 +/- 10mm/s, used to detect Pulp suspension filtration rate, in line with ISO 5267-1 international standards.
Vertical design, motor and drying system separation, small vibration, low noise, high dehydrating efficiency, Rotation speed of 2800 rpm, dehydrating weight 0-500g, accurate timing, easy to use.
Measurement range 0-4mm, resolution 0.001mm, contact pressure 100 +/- 10kPa, contact area 2 +/- 0.05cm ², automatic reciprocating motion to complete thickness measurement.
Measurement range 0-4mm, contact pressure 100kPa, equipped with dial indicator mechanism, can achieve accurate thickness detection, suitable for a variety of sheet materials.
Measurement range 0~ 1000ml/min, pressure difference 0.1~ 2.0kpa, stainless steel end cap and pure copper valve anti-corrosion structure, built-in fixture to avoid rubber pad peeling, suitable for a variety of materials Air Permeability accurate test.
Measurement range 0~ 1000ml/min or 0~ 17µm/(Pa · s), test area 10.0 +/- 0.05cm ², differential pressure accuracy +/- 0.01kPa, clamp ring coaxiality less than 0.05mm, suitable for medium Air Permeability paper testing.
Measurement range 0~ 1000ml/min, test area pressure accuracy of +/- 0.01kPa, equipped with 10cm ² standard test area and 35.68mm clamping ring, support different duration test.
With manual and automatic temperature compensation function, Measurement range 0-6 pF, resolution up to 0.01 pF, support fluorine Ion concentration value display, easy operation and digital display intuitive and accurate.
Measurement range 0~ 1000ml/min, test area 10cm ², test area pressure difference 1kPa, suitable for a variety of industrial paper ventilation performance detection.
Using the measuring Rod positioning measurement method, the speed range is 0.01-10 m/s, the flow measurement error is less than or equal to 1.5%, with liquid crystal display and LED backlight, supporting -10 ° C to 50 ° C environment temperature, simple and stable structure.