Electric High-Shear Disperser

The electric high-shear disperser drives the rotor to rotate at high speed via a motor, generating intense shear forces in the stator gap to break, mix, and homogenize materials. It is used for dispersing and emulsifying liquids and solid particles in industries such as coatings and inks, achieving material refinement and stability.
Selection
When selecting, consider the viscosity of the material to match the motor power, determine the capacity specifications based on the processing volume, choose the speed control function according to the process requirements, opt for stainless steel material for corrosive media, and confirm the explosion-proof level and safety protection devices based on the operating environment.

Terms

Standards

Instruments

With a speed of up to 30000rpm and a processing viscosity of 10000mPas, the claw-type high-shear structure and interchangeable stator and rotor provide triple safety protection and continuous 6-speed regulation, ensuring efficient dispersion and durability.

$ 1224.00

Set dispersion and Stir functions in one, the two processes of dispersion and homogenization are completed by one machine, with high efficiency, good mixing effect and easy cleaning. Speed range 100~ 8000rpm, maximum processing viscosity 100000mPa.s, electric lifting mode is simple and convenient to operate.

$ 493.00

Adopt spring electric lifting system, Travel 200mm; Frequency conversion motor Power 750W, speed range 60-8000rpm; with dispersed impeller and sand grinding blades, can be adapted to jacket chill down Mixing Tank for multi-purpose experimental operation.

$ 733.00

Stir, sand grinding, dispersion multi-function, speed range 60-8000rpm, electric lift Travel 250mm, frequency conversion motor running smoothly and low noise, high digital PID control accuracy, suitable for a variety of specifications Mixing Tank.

$ 562.00

Using high-speed swirl/spin rotor and precision stator to achieve high linear speed shearing, Speed range 50~ 6000rpm, Processing capacity 5~ 30L, with electric lifting and emergency stop Safety protection functions.

$ 5632.00

Using high-speed swirl/spin rotor and precision stator to achieve 50-6000rpm frequency conversion speed regulation, the maximum processing viscosity of 8000CP, electric hydraulic lifting operation is simple, with emergency stop Safety protection function.

$ 5632.00

Rotation speed of 3000rpm, Processing capacity 20m ³/h, using three groups of stator structure to achieve strong impact and shear, with strong self-priming capacity and low lift transport function, can operate stably for a long time.

$ 4642.00

Using high-speed swirl/spin rotor and precision stator to pRoduce strong hydraulic shearing and centrifugal extrusion, Speed range 50-6000rpm, Processing capacity 5-30L, with electric lift and emergency stop protection function.

$ 5632.00

Using high-speed swirl/spin rotor and precision stator to pRoduce strong hydraulic shearing and centrifugal extrusion, Speed range 50-4000rpm, maximum processing viscosity 8000CP, electric hydraulic lifting operation is simple.

$ 6956.00

Using high-speed swirl/spin rotor and precision stator to achieve stepless speed regulation of 50-6000rpm, maximum processing viscosity of 8000CP, with electric lifting and emergency stop protection functions to meet the needs of continuous experiments.

$ 5632.00

Rotation speed up to 3000rpm, Processing capacity 16m ³/h, using three-stage stator structure to achieve strong impact and shear, double-end mechanical sealing without leakage, jacket chill down design to support long-term operation.

$ 4020.00

The use of electric lifting system to achieve 320mm Travel adjustment, frequency control range of 60-6900rpm, equipped with multi-specification impeller and chill down jacket structure, can meet the needs of stirring and dispersing under different material viscosity.

$ 1006.00

Speed up to 30000rpm, the maximum processing viscosity of 10000mPa.s, the use of claw high shear head structure and triple safety protection, can quickly homogenize tissue samples, stator and rotor interchangeable cost savings.

$ 1263.00

Using electric hydraulic lifting mode, easy to operate; Speed range 50~ 6000rpm, Power 750W; with emergency stop button and overload protection function to ensure continuous and safe operation of the experiment.

$ 5632.00

Rotation speed up to 3000rpm, Processing capacity 11m ³/h, three sets of rotating stator structure to achieve strong impact and shear, double mechanical sealing design to ensure no leakage, jacket chilled down to support long-term operation.

$ 3193.00

Articles

When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Capacity Matching for Laboratory Small Dispersers and Pilot Dispersers
This article primarily discusses how to select the appropriate disperser for laboratory research and process development.
Laboratory dispersers achieve efficient dispersion of paint pigments.
This article introduces how laboratory dispersers efficiently disperse paint pigments. They break up pigment agglomerates through mechanical actions such as shear force, involving three stages: wetting, dispersing, and stabilizing.
Selection of disperser speed range and matching of dispersing disc form with container
This article discusses the technical points in the selection of a disperser, including the speed range, the form of the dispersion disc, and the matching with the container.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Application of Two-Step Method with Pre-Coating and Fine-Coating in Eliminating Bubble Defects for Dual-Blade Coater
The dual-blade coater employs a two-step method of pre-coating and precision coating to eliminate bubble defects during the coating process. In the pre-coating stage, high shear force is applied to break the bubbles in the slurry, causing them to rupture and rise to the surface. The precision coating stage then precisely controls the coating thickness, removing any remaining bubbles to form a uniform wet film.
The impact of the disperser impeller structure on dispersion effectiveness.
This article mainly discusses how the impeller structure of a disperser affects the dispersion effectiveness. The impeller is the core component of a disperser, and its design directly influences the uniformity and stability of the final mixture.
Application of High-Speed Disperser in the Preparation of Water-Based Inks
This article introduces the application of a high-speed disperser in the preparation of water-based inks. It first explains the working principle of the equipment, which involves generating shear forces through high-speed rotation to disperse particles.