Glass sensitive film of 4.5 mm and point ceramic liquid junction, suitable for micro sample measurement, Operating temperature range 0~ 80 ℃, providing stable reference potential.
It can simultaneously test two devices, with a maximum load of 2kg and a drop height of 60 to 150mm. It uses pneumatic components and PLC control to achieve high-speed consistent testing, and has automatic stop and count functions.
The equilibrated refrigeration technology makes the temperature fluctuation small, and the fluorine-free R134 refrigerant is more energy-saving and environmentally friendly. Temperature range 0~ 60 ℃, Humidity Control Range 50~ 90%, intelligent humidification system and mirror stainless steel liner.
Using 0.5-2 μL micro-volume sample detection, the optical path accuracy is 0.001mm, the detection concentration is 50 times that of conventional equipment, and the sample recovery and 6-second rapid analysis are supported.
Driven by serial micro motor, the output torque reaches 95.5N.cm, with stepless speed regulation and automatic overload protection to ensure constant speed operation and experimental safety.
Adopt dual-axis constant force lifting system, lifting Travel 400mm; Rotation speed up to 8000rpm, linear speed up to 41m/s; High-speed dispersion disc generates strong shear force to achieve uniform dispersion and suspension effect of materials.
The equilibrate refrigeration technology makes the temperature fluctuation small, equipped with fluorine-free R134 refrigerant to achieve energy saving and environmental protection, high temperature control accuracy and constant humidity, liner mirror stainless steel material is easy to clean and maintain, and the volume is 100L to meet the needs of various experiments.
Frequency 7MHz, Probe diaMeter 6mm, can be measured thin-walled and small arc surface, minimum pipe diaMeter Φ 15mm, Measurement range 0.75-80 mm, suitable for different environmental conditions.
Micro-gravure plate coating method to achieve ultra-thin uniform coating, Spreader thickness range is wide; integrated online corona treatment makes the substrate surface tension up to 72dyne/cm; drying box temperature control accuracy +/- 3 ℃ to meet different solvent drying needs.
Using irreversible color technology, accuracy +/- 1 ° C to +/- 4 ° C, oil and water vapor resistance, providing four-grid temperature monitoring, size 4x11mm, 10 sheets per copy.
Irreversible color change records the highest temperature, four-grid design can monitor multiple temperature points simultaneously, accuracy +/- 1 ° C to +/- 4 ° C, oil and water vapor resistance, instant Response for field application.
Using irreversible color technology, accuracy +/- 1 ° C to +/- 4 ° C, four-grid temperature point design can monitor multiple temperature thresholds at the same time, Response instant and oil-resistant water vapor, providing long-term temperature recording.
Complete the sterilization of small metal Glass appliances within ten seconds, the maximum temperature is 300 ° C, the temperature control accuracy is +/- 5 ° C, and the built-in over-temperature protection device ensures the safe operation.
The small sample adapter only needs 2-16ml sample volume, temperature accuracy of +/- 0.1 ℃, supports stepless speed measurement and automatic lifting system, with viscosity and temperature correction function and a variety of data storage methods.
Elliptical trajectory vertical vibration design, vibration Frequency 660 times/min, maximum load 30KG, equipped with automatic cooling down system to maintain sample temperature stability, closed structure to reduce noise and pollution risk.