Particle Granularity Distribution Analyzer

The particle size distribution analyzer measures the size distribution of particles in a sample through laser diffraction or dynamic light scattering. The instrument emits a laser beam through a suspension and calculates the particle size based on the scattering angle or fluctuation rate. It is used in production quality control processes such as monitoring the uniformity of paint pigments, the dispersion stability of inks, and the distribution of fillers in paper.
Selection
When selecting, consider that the measurement range should cover the particle size of the samples. Wet methods are suitable for suspensions, while dry methods are suitable for powders. The dispersion system should match the sample properties, with ultrasound used to prevent agglomeration and stirring to ensure uniformity. The software functions should meet analysis requirements, and compliance documents should be complete. Maintenance costs and accessory supply should also be included in the evaluation.
Optical inspection principle
test principle
Special purpose

Terms

Standards

Instruments

Measurement range 0.5-3000 μm, maximum resolution 0.1μm, support more than 30 image analysis functions, Particle size distribution and morphology analysis.

$ 5237.00

Test range 0.5~ 3000μm, Maximum magnification 4000 times, can analyze the number of particles, area, circumference, diaMeter, aspect ratio and other distribution data, support a variety of formats of test report output.

$ 6205.00

With two movements of reciprocating and top-beating vibration, the screening efficiency is high and does not block the screen surface. It can be adapted to a set of screening screens of Φ 200, Φ 75, and Φ 100. The number of swirl/spins is 290 +/- 6 times/minute, and the number of beats is 156 +/- 3 times.

$ 1763.00

The use of hardened steel double-channel structure ensures dimensional stability, with a range of 0-100 μm and 10 μm Graduation, the film can be scraped in 3 seconds and the particle distribution can be evaluated.

$ 848.00

The image method is used to analyze the particle morphology and particle size, the test range is 1~ 3500 μ m, the system magnification is 4000 times, the automatic segmentation success rate exceeds 93%, and paraMeters such as length-diaMeter ratio and sphericity can be counted.

$ 5366.00

100L/min Sampling flow rate and six particle size channel detection, equipped with long life laser Illuminant and imported air pump, support Touchscreen operation and USB data export function.

$ 10578.00

Using 50L/min Sampling flow rate and six particle size channel synchronous detection, equipped with semiconductor laser Illuminant and Touchscreen control, built-in thermal printer supports real-time data output, Continuous Operating Time up to 5 hours.

$ 8461.00

The image method is used for particle morphology analysis, the measurement range is 0.1~ 3000μm, the total magnification is 8000 times, and the automatic segmentation and measurement of various geometric paraMeters are supported, and the operation is efficient.

$ 8949.00

The image method is used for particle morphology analysis, the measurement range is 0.1~ 3000 μ m, the total magnification is 8000 times, and it has the functions of automatic segmentation and measurement of various geometric paraMeters.

$ 12176.00

Image segmentation technology is used to process overlapping dust and maintain particle prototype; Measurement range is 0.1~ 3000μm, repeatability error ≤ +/- 1%; support custom particle size classification and various image processing methods.

$ 9998.00

Using light scattering principle to detect 0.3-10 μ m particle size, Sampling flow rate 28.3L/min, built-in lithium battery supports 6 hours of work, can directly save data to U disk, equipped with thermal printer for on-site output.

$ 3922.00

With six-channel particle size detection and 2.83L/min Sampling flow rate, using laser Illuminant life of over 30,000 hours, support UCL calculation and Built-in Printer, AC-DC dual-use can work continuously for more than 6 hours.

$ 848.00

With six particle size channel detection capability, sampling capacity of 2.83L/min, built-in lithium battery supports 6 hours of continuous operation, using semiconductor laser Illuminant and color Touchscreen design.

$ 2510.00

Made of stainless steel, the range is 0-100μm, Graduation is 5μm, and the plane flatness of the scraper is 0.003mm to ensure accurate and reliable particle fineness measurement.

$ 138.00

With six-channel particle size detection capability, Sampling flow rate 2.83L/min, using long-life laser Illuminant to ensure Stability, built-in thermal printer and support AC and DC power supply, can work continuously for more than 6 hours.

$ 1171.00

Articles

How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Laser particle size analyzer measures the particle size distribution of spray powder.
Laser particle size analyzers measure the particle size distribution of sprayed powder based on the principle of light scattering, which is critical for coating uniformity and adhesion. During measurement, the powder must be dispersed in a suitable medium to avoid agglomeration, and tests should be repeated to ensure accuracy.
Laser particle size analyzer analyzes particle size distribution of paint pigments.
This article introduces the application of laser particle size analyzers in analyzing the particle size distribution of paint pigments. It mentions that the particle size distribution of pigments affects the optical properties, stability, and rheological characteristics of coatings.
The role of the screening analyzer in pulp fiber morphology analysis
The screening analyzer separates pulp fibers through standard sieves to analyze their length distribution. Morphological parameters such as fiber length and coarseness directly affect paper properties like strength and bulk.
Sieve Residue Analyzer and Sieve Analysis for Determining Pigment Particle Size Distribution
This article introduces how the sieve residue analyzer measures the particle size distribution of pigments through mechanical sieving.
If the three temperature parameters of the melt flow indexer for testing plastic fluidity are not properly adjusted, all data will be invalid.
When testing the flowability of plastics with a melt flow indexer, temperature control is crucial. There are three key temperature parameters: first, the barrel set temperature; second, the uniformity of temperature distribution; and third, the stability of temperature control.