Ultra Constant Temperature Bath

The ultra-thermostatic bath maintains a constant temperature of the liquid inside the tank through a heating and cooling system and a circulation pump, and is used for laboratory temperature control scenarios such as calibrating thermometers and maintaining constant temperature for samples.
Selection
When selecting, consider the temperature range and fluctuation index. The tank size should match the sample volume. Pay attention to the compatibility of the thermal conductive medium. Choose between compressor or electronic refrigeration methods based on the frequency of use. Balance safety protection with the convenience of daily maintenance.

Terms

Standards

Instruments

Temperature range covers -40 to 100 ℃, Temperature Fluctuation accuracy to +/- 0.05 ℃, resolution up to 0.01 ℃, and supports internal and external double cycle mode to meet the needs of various experiments inside and outside the tank.

$ 1285.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 60 ℃ and no drift, rotary oscillation ensures uniform mixing of samples.

$ 740.00

Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0-300rpm adjustable, swing amplitude 20mm, to meet different experimental needs.

$ 932.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity of +/- 0.0050 ℃, equipped with PID automatic temperature control program and High Accuracy PT100 Sensor to ensure accurate and stable temperature control.

$ 2600.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, integrated PID automatic temperature control and High Accuracy PT100 Sensor to ensure stability and accuracy.

$ 1408.00

Temperature Uniformity of +/- 0.0050 ℃, resolution of 0.0001 ℃, U-shaped reflux cycle design to ensure uniform flow field, no heat centrifugal pump to avoid their own heat impact temperature field, with multiple Safety protection functions.

$ 2420.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, with low water level protection and temperature runaway alarm and other safety functions, accurate and stable temperature control.

$ 1703.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, integrated PID automatic temperature control program, Temperature Uniformity +/- 0.0050 ℃, resolution 0.0001 ℃, with multiple Safety protection devices.

$ 3909.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and temperature runaway alarm function to ensure the safety and stability of the experiment.

$ 14703.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and anti-dry burning functions, to ensure the safe and stable operation of the experiment.

$ 1335.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.0050 ° C, and multiple safety functions such as low water level protection and temperature runaway alarm.

$ 1927.00

Adopt PID automatic temperature control program, Temperature Uniformity +/- 0.0050 ℃, resolution up to 0.0001 ℃. No heat centrifugal circulation pump to avoid its own heat effect temperature field, equipped with multiple Safety protection devices.

$ 2555.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Vacuum adsorption coating machine solves the flatness challenge in the transfer of ultra-thin graphene films.
The vacuum adsorption coating machine transfers graphene films smoothly onto target substrates through controlled negative pressure, solving issues such as wrinkling, tearing, and contamination often encountered with traditional methods.
Superhydrophobic surface coating is applied to the microstructure substrate using a film coating machine.
This article introduces the coating process of superhydrophobic surface coatings on microstructured substrates. Superhydrophobic coatings feature high water contact angles and low rolling angles, making them widely used in applications such as anti-fouling and waterproofing.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
To determine if an ultrasonic cleaner cleans effectively, first understand the two key parameters: frequency and power.
This article mainly discusses how to achieve thorough cleaning with an ultrasonic cleaner, emphasizing that the key factors are frequency and power. The frequency determines the size and penetrating ability of the bubbles generated during cleaning, while the power provides the necessary energy for the cleaning process.