Temperature range covers -40 to 100 ℃, Temperature Fluctuation accuracy to +/- 0.05 ℃, resolution up to 0.01 ℃, and supports internal and external double cycle mode to meet the needs of various experiments inside and outside the tank.
With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.
With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.
With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.
Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 60 ℃ and no drift, rotary oscillation ensures uniform mixing of samples.
Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0-300rpm adjustable, swing amplitude 20mm, to meet different experimental needs.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity of +/- 0.0050 ℃, equipped with PID automatic temperature control program and High Accuracy PT100 Sensor to ensure accurate and stable temperature control.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, integrated PID automatic temperature control and High Accuracy PT100 Sensor to ensure stability and accuracy.
Temperature Uniformity of +/- 0.0050 ℃, resolution of 0.0001 ℃, U-shaped reflux cycle design to ensure uniform flow field, no heat centrifugal pump to avoid their own heat impact temperature field, with multiple Safety protection functions.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, with low water level protection and temperature runaway alarm and other safety functions, accurate and stable temperature control.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, integrated PID automatic temperature control program, Temperature Uniformity +/- 0.0050 ℃, resolution 0.0001 ℃, with multiple Safety protection devices.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and temperature runaway alarm function to ensure the safety and stability of the experiment.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and anti-dry burning functions, to ensure the safe and stable operation of the experiment.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.0050 ° C, and multiple safety functions such as low water level protection and temperature runaway alarm.
Adopt PID automatic temperature control program, Temperature Uniformity +/- 0.0050 ℃, resolution up to 0.0001 ℃. No heat centrifugal circulation pump to avoid its own heat effect temperature field, equipped with multiple Safety protection devices.