Low-temperature Circulating Bath

A low-temperature water bath maintains a constant-temperature liquid environment through a refrigeration system, used for sample cooling, reaction control, or material testing. It is employed in laboratories for handling heat-sensitive substances, conducting crystallization experiments, or viscosity measurements.
Selection
When selecting, consider the temperature range and stability requirements, and match the sample capacity. Check the cooling power and temperature control accuracy, and pay attention to the corrosion resistance of the tank material. Inspect the safety protection features, and choose between benchtop or floor-standing models based on available space.

Terms

Standards

Instruments

Imported Pt100 temperature sensor and dual Compressor refrigeration system, rapid cooling and low noise, Temperature Fluctuation +/- 0.05 ℃, 6L volume Tank with 8L/min circulating pump to ensure Temperature uniformity.

$ 958.00

Imported PT100 temperature sensor and double Compressor cascade refrigeration system, high refrigeration efficiency and low noise, Temperature Fluctuation +/- 0.05 ℃, Tank volume 30L, Circulating pump Flow rate 10L/min to ensure Temperature uniformity.

$ 3610.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.0050 ° C, and multiple safety functions such as low water level protection and temperature runaway alarm.

$ 1904.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, with low water level protection and temperature runaway alarm and other safety functions, accurate and stable temperature control.

$ 1682.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and temperature runaway alarm function to ensure the safety and stability of the experiment.

$ 14520.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and anti-dry burning functions, to ensure the safe and stable operation of the experiment.

$ 1319.00

The double Compressor and cascade refrigeration system are used to cool down quickly and have low noise; the overall foaming insulation of the Tank body reduces the loss of cooling capacity, the flow rate of the circulating pump is 10L/min to ensure Temperature uniformity, and the Temperature Fluctuation is only +/- 0.05 ℃.

$ 1633.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices including low water level protection and temperature runaway alarm functions.

$ 6268.00

The use of non-heat centrifugal circulating pump to avoid affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, with low water level protection and Compressor multiple protection functions to ensure safe and stable operation.

$ 982.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes Temperature Uniformity +/- 0.0050 ℃, with low water level protection and Compressor multiple safety protection functions.

$ 7153.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety functions, optional program temperature control and Communication interface.

$ 1301.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices including low water level protection and temperature runaway alarm functions.

$ 1822.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety protection, optional program temperature control and magnetic stirring function.

$ 1771.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices including low water level anti-dry burning and Compressor overload protection functions.

$ 6074.00

The non-heat centrifugal circulating pump is adopted to avoid its own heat generation affecting the temperature field. The U-shaped return design realizes Temperature Uniformity +/- 0.0050 ℃, and has multiple safety functions such as low water level protection and temperature loss alarm.

$ 3719.00