Lead coating thickness Gauge

The lead coating thickness gauge operates on the principle of X-ray fluorescence, where the detector receives the characteristic X-rays excited by the coating and calculates the relationship between lead element intensity and thickness. It is used to measure the thickness of lead plating on metal substrates, ensuring the soldering quality of electronic components and compliance with environmental regulations.
Selection
When selecting, consider that the measurement range should cover the sample thickness, the substrate type should match the instrument's calibration curve, X-ray protection must comply with safety standards, the ambient temperature should adapt to production line conditions, and precision should be regularly verified using standard samples.

Terms

Standards

Instruments

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Dedicated to lead ion composite ElectRode calibrated solution, 250ml standard Encasement, provides a stable lead Ion concentration reference, to ensure ElectRode Measurement accuracy and long-term Stability.

$ 110.00

ElectRode composite structure, equipped with 60mL reference filling solution and calibrating solution, built-in ionic strength modifier, support accurate lead Ion concentration measurement, matching polishing strip for easy maintenance.

$ 309.00

Measurement principle using ultrasonic, Measurement range 50~ 3800μm, accuracy +/- (2μm + 3%), suitable for concrete and fiberglass substrate Coating thickness detection.

$ 2939.00

Measurement thickness up to 25mm with an error of only +/- 3% with removable FJS Probe for thick protective coating substrates, statistical capabilities and 250,000 Data storage capabilities.

$ 2115.00

Measurement principle using ultrasonic, Measurement range 13~ 1000μm, accuracy +/- (2μm + 3%), suitable for wood, plastic and other substrates polymer Coating thickness detection.

$ 2652.00

Using magnetic Induction and eddy Current principle simultaneous measurement composite coatings, Measurement range 0~ 1500μm, error +/- 1%, can display a single coating and zinc layer thickness, suitable for the accurate detection of ferrous and non-ferrous substrates.

$ 1622.00

Using magnetic Induction and eddy Current dual principle, it can simultaneously measure paints and zinc layer thickness. Measurement range is 0-1500 μm, accuracy is +/- 1%, suitable for composite coating system inspection.

$ 1387.00

Measurement range of 5-500μm with a three-blade design, LED Illumination Microscope and swirl/spin system for accurate assessment of Coating thickness and substrate defects.

$ 296.00

Measurement range 0-3000μm, error +/- 3%, easy to carry and high Stability, suitable for a variety of Coating thickness detection.

$ 461.00

Adopt magnetic Induction principle measurement Coating thickness, Measurement range 0-1250μm, resolution up to 0.1μm, with automatic identification Probe, Data storage and upper and lower limit alarm function, aluminum shell is sturdy and durable.

$ 296.00

Support multi-coating system measurement, can measure up to 3 Coating thickness, Measurement range 13~ 1000μm, error +/- (3% H + 2) μm, with 100000 data storage capacity and a variety of Data output methods.

$ 3462.00

Articles

Pencil hardness tester rapidly evaluates scratch resistance of paint film.
This article introduces how to quickly assess the scratch resistance of paint films using a pencil hardness tester. During the test, standard pencils (ranging from 6B to 9H) are used to scratch the coating at a fixed angle and pressure to observe whether scratches occur.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Application of Film Pencil Hardness Tester in Coating Scratch Resistance Testing
The paint film pencil hardness tester is an instrument used to evaluate the scratch resistance of coatings. It works by scratching the surface of the coating with a pencil of known hardness under a fixed load, and then assessing the hardness grade based on whether scratches are produced.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Classification standards for determining the hardness of coatings using a pencil hardness tester.
This article introduces the method of measuring the hardness of coatings using a pencil hardness tester. It involves using pencils of varying hardness to scratch the coating and observing whether scratches are produced to determine the hardness grade, ranging from 6B to 9H.
Atomic Absorption Spectrometer for Determining Heavy Metal Content in Coatings
This article introduces a method for determining the content of heavy metals such as lead, cadmium, chromium, and mercury in coatings using atomic absorption spectroscopy. The method is based on the absorption of characteristic wavelength light by atoms for quantification. It requires acid digestion pretreatment of coating samples and optimization of instrument conditions to improve accuracy.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.
Differences in Measurement Principles Between Magnetic Method and Eddy Current Method for Coating Thickness Gauges
Coating thickness gauges primarily utilize two measurement principles: magnetic method and eddy current method. The selection of the method should be based on the characteristics of the substrate material to ensure measurement accuracy.
Key Operational Points and Influencing Factors of Pencil Hardness Method for Determining Coating Film Hardness
The pencil hardness test is a method used to evaluate the scratch resistance of a coating by making marks on the paint film with pencils of known hardness. During the operation, a uniformly cured sample is prepared, and calibrated pencils are used to make marks at a 45-degree angle with a fixed force, aiming to identify the highest hardness grade that does not scratch through the paint film.