Ozone Test and Measurement Instrument

The ozone test chamber generates a quantitative amount of ozone to simulate an atmospheric ozone environment, detecting the aging and cracking of materials such as rubber and plastics under ozone exposure. It is used to evaluate the ozone resistance of materials and guide product formulation improvement and quality control.
Selection
When selecting, consider that the dimensions of the test chamber match the sample, the ozone concentration range covers application requirements, the temperature and humidity control precision meets standard specifications, the corrosion resistance of materials ensures long-term stability, the operation interface is simple and user-friendly, and maintenance costs align with the budget.

Terms

Standards

Instruments

Adopt silent ozone generator and UltravioletDetector, ozone concentration control accuracy +/- 2pphm, support static tensile and dynamic tensile test, Temperature Uniformity ≤ 2 ℃ to meet a variety of test conditions

$ 8529.00

Adopt independent ozone concentration controller for long-term stable non-drift, equipped with high voltage silent discharge tube ozone generator, concentration range 10~ 1000pphm, Temperature Fluctuation +/- 0.5 ℃, support static tensile specimen and sample rack speed 1~ 2rpm.

$ 11079.00

High Accuracy PID control technology, temperature fluctuation +/- 0.5 ℃, equipped with independent ozone concentration controller long-term stable non-drift, support static tensile specimen and program operation mode.

$ 13128.00

Imported stainless steel liner and independent ozone concentration controller, temperature control accuracy of +/- 0.5 ℃, equipped with static tensile fixture and rotational speed adjustable sample rack, support long-term stable operation.

$ 10643.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, temperature fluctuation is only +/- 0.5 ℃.

$ 12015.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, Temperature Fluctuation control within +/- 0.5 ℃.

$ 16017.00

SUS304 stainless steel inner box and double insulation structure, equipped with 360 degree swirl/spin sample holder and precise ozone concentration control, temperature fluctuation +/- 0.5 ℃, support static dynamic tensile test, suitable for rubber durability research.

$ 5899.00

Measurement range 0~ 2.5mg/L, resolution 0.01mg/L, small size and easy to carry, reduce the requirements for users and provide reliable detection results.

$ 264.00

Using UV absorption principle to detect ozone, range 0-2.00 mg/L can be selected to 20.00mg/L, accuracy error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support flameproof design and a variety of signal output, suitable for complex industrial environment.

$ 1364.00

Measurement range 0~ 2.5mg/L, resolution 0.01mg/L, Repeatability 1%, small size and easy to carry, reduce the use of personnel requirements, to provide reliable detection results.

$ 286.00

With 0~ 100ppm ozone detection range and T90 ≤ national standard Response Time, support remote paraMeter configuration and zero automatic correction, explosion-proof IP66 protection is suitable for harsh industrial environments.

$ 716.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360-degree swirl/spin sample holder and 12-16mm/s gas flow rate, support 0-9999 hours time setting, with leakage overtemperature multiple safety protection.

$ 13209.00

Supports simultaneous detection of 4 gases, Integrated Temperature and Humidity Detection, Compatible with Diffusion and Pump Sampling methods, with Internet of Things remote monitoring function, Protection Rating IP66, Operating temperature range -40~ 55 ℃.

$ 635.00

The heating wire is used to achieve rapid heating, the temperature fluctuation is only +/- 0.5 ℃, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, supports dynamic static test mode, and meets a variety of test needs.

$ 14419.00

Supports simultaneous detection of 4 gases and integrated temperature Humidity monitoring, adopts pump suction and diffusion double Sampling method, has IoT remote monitoring function, Protection Rating IP66, Operating temperature range -40~ 55 ℃.

$ 1050.00

Articles