Ammonia Leak Alarm

Ammonia leak detectors use electrochemical sensors to detect the concentration of ammonia in the air. When the concentration exceeds a preset threshold, they trigger audible and visual alarms. These devices are used in locations such as cold storage facilities and chemical plants where ammonia refrigerants or raw materials are present, to prompt personnel to take ventilation or evacuation measures.
Selection
When selecting, ensure the detection range covers 0-100 ppm, with explosion-proof certification and an IP65 protection rating. The sensor lifespan is approximately 2 years, and calibration cycles and false alarm rates should be evaluated. Prioritize models with 4-20 mA or RS485 outputs for easier system integration.

Instruments

Frequency range 20KHz to 100KHz, Sensitivity indicated by LED and sound, weight of only 140 grams for portable, suitable for a variety of gas and air leak detection scenarios.

$ 301.00

Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.

$ 110.00

Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.

$ 1806.00

Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.

$ 209.00

250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.

$ 127.00

Adopting high voltage detection technology, it can sensitively find defects such as coating pinholing and bubbles, equipped with sound and light alarm system, and powered by nickel battery, which is convenient for field operation.

$ 590.00

The filling liquid capacity of 30mL, the use of PTFE bottles, Dimension 65mm high × 30mm diaMeter, weight of only 20g, suitable for the maintenance of Ammonia Gas sensing electRode.

$ 135.00

ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.

$ 135.00

Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.

$ 164.00

ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, copper ion type, capacity 480 ml, to ensure ElectRode performance stability and measurement accuracy.

$ 135.00

ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, providing bromine ion type and 480mL capacity to ensure stable ElectRode performance.

$ 135.00

Glass-lined, FRP, epoxy coal asphalt coatings of different thicknesses can be mass tested by high voltage detection technology. When the coatings have defects such as pinholing and bubbles, the instrument will emit bright sparks and sound and light alarms.

$ 1230.00

Designed for Ammonia Gas Sensitive Compound ElectRode, it provides a stable reference potential to ensure accurate measurement. The Encasement specification is 250ml, which is suitable for long-term monitoring applications.

$ 143.00

Colorimetric measurement based on Nasler method, Measurement range 0.00-10 mg/L, providing 100 tests, accurate determination of ammonia nitrogen concentration by Color intensity change.

$ 212.00

Colorimetric digestion integrated tube operation, no liquid transfer; water samples for more than 10 measurements to take the average value; ammonia nitrogen detection limit of 0.01mg/L, measurement error ≤ +/- 5%, data storage 30,000.

$ 1493.00