The 10x30mm standard size design ensures a perfect match with the SH1117 Tester, providing accurate gel strength measurement results.
Using copper plate platform and long-life heating tube, PID intelligent temperature control accuracy +/- 1 ℃, rapid heating to 200 ℃ only 10 minutes, suitable for a variety of Resin materials gel time determination.
Using Platinum Sensor and Gel KCL Reference Solution, Operating temperature range is 0~ 60 ℃ to ensure stable reference potential and good sensing ability.
Frequency adjustable continuously, stable operation and low noise, the device is suitable for gel treatment, molecular hybridization and X-ray film Development, etc.
Working Frequency 0-240rpm continuously adjustable, equipped with 340 * 250mm tray, support swing oscillation mode, low running noise and stable performance, suitable for gel treatment and molecular hybridization and other experimental scenarios.
Built-in temperature resistor real-time sensing sample temperature, gel KCL reference solution to ensure long-term stability of ElectRode, Measurement range 0~ 14pH, suitable for a variety of liquid environments.
Aluminum alloy working platform and long life heating tube, Temperature range RT +~ 550 ℃, temperature error +/- 1 ℃, equipped with PID intelligent temperature Control system, can be customized heating Platform size according to demand.
The motor is used to drive the top edge to rise, the edge length is 150mm, and the rising rate is 3mm/min, which can accurately test the dynamic anti-cracking performance of the material against the crazing expansion of the substrate, and the operation is light and stable.
Using plastic shell with 1 Meter BNC interface cable, specification is Φ 12mm × 120mm, built-in 3mol KCl gel reference solution without maintenance, Measurement range 0-14pH and 0-60 ℃, suitable for a variety of detection scenarios, providing stable and accurate acid alkalinity measurement.
Using copper plate working platform and long life heating tube, PID intelligent temperature control to achieve +/- 1 ℃ accuracy, Temperature range RT + 10~ 300 ℃, with automatic thermostatic function, easy to operate.
Equipped with automatic centering device to avoid eating unilateral problems, maximum load 50Kg, Test speed range 0-100mm/min, support dynamic Impedance test and a variety of damage strength test.
Using Dynamic Low Temperature Nitrogen Adsorption Method and High Sensitivity Sensor, the test range from 0.0005m ²/g has no upper limit, the repeatability error ≤ +/- 3%, and the single sample test is completed in about 3 minutes.
With 2-level accuracy and +/- 2% Indication Error, it supports three test modes of real-time tracking, peak holding and first peak, and can store 99 sets of data and automatically calculate statistical values.
With 1 level accuracy and +/- 1% Indication Error, it supports three test modes of real-time torque tracking, peak holding and first peak, and can store 99 sets of data and automatically calculate statistical values.
With 1 level accuracy and +/- 1% Indication Error, supports automatic conversion of three units and 99 sets of data storage, can set peak hold time and upper and lower limit alarms, equipped with dedicated software for data analytics and Linear dispersion display.