Desktop Transmission SpectroPhotoMeter

Desktop transmission spectrophotometers operate by illuminating transparent or translucent samples with a light source. The spectrophotometric system analyzes the spectral composition of the transmitted light, while a detector captures the data and calculates color parameters. These instruments are used to measure the transmission color characteristics of materials such as liquids and films, playing a crucial role in industries like ink and plastics for controlling product quality and consistency.
Selection
When selecting, consider matching the sample type to the instrument's measurement range, ensuring the spectral resolution meets accuracy requirements, confirming instrument repeatability for data stability, aligning software functionality with workflow needs, and verifying that maintenance costs and calibration convenience meet usage conditions.
Type
Measurement method
Caliber
light source
integrating sphere
Chromatic value repeability
Measurement shape
software
Special features

Terms

Standards

Instruments

Repeatability accuracy of dE * ab ≤ 0.005 and Inter-instrument Agreement ≤ 0.12 with differential light spectrum engine and dual optical path design. Equipped with pulse xenon arc and LED dual Illuminant, supports automatic switching of four measurement diameters, and has the function of temperature Humidity compensation.

$ 16178.00

The width is 5cm, the optical path is 10mm, and the dimensions are 12.5 × 52.5 × 45mm, which is suitable for the use of Spectrophotometer to ensure Optical inspection detection accuracy.

$ 114.00

Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.

$ 101.00

The width is 3cm, the optical path is 10mm, and the dimensions are 12.5 × 32.5 × 45mm. As a special accessory for Spectrophotometer, it ensures the stability of the optical path and the accuracy of measurement.

$ 106.00

Full digital speed control system and stepper motor drive, Force Indication Error ≤ +/- 0.5%, with four test modes, support automatic transmission and Data storage functions.

$ 3341.00

Driven by all-digital speed control system and stepper motor, the Force Indication Error ≤ +/- 0.5%, supports four test modes including fixed height force measurement value and fixed deformation force measurement value, and has automatic transmission and overload protection functions.

$ 3341.00

Repeatability accuracy up to dE * ab ≤ 0.005 and Inter-instrument Agreement up to dE * ab ≤ 0.15. Equipped with pulse xenon arc and LED Illuminant, four measurement diameters and high definition cameras, support SCI/SCE simultaneous measurement and Humidity compensation.

$ 13919.00

The uniformity of the transmission surface exceeds 90%, the standard four-speed Color temperature is adjustable, the illuminance adjustment range is 0-120000Lux, and the thickness dimming knob is equipped to achieve precise control. Illuminant has no stroboscopic and the lifespan is more than 10,000 hours.

$ 5237.00

It has 2000N range and 0.5% force value accuracy, supports four test modes and automatic transmission function, can freely set Graduation and automatically store data, with overload protection and emergency shutdown device.

$ 3667.00

Equipped with 7 kinds of Impact devices and automatic identification, support 6 kinds of Hardness standard conversion and tensile strength conversion, embedded thermal printer timely output report, Bluetooth transmission data, can store 100 sets of test data.

$ 396.00

Coaxial focusing mechanism with coarse fretting, fretting grid value of 2 μ m, equipped with two sets of illumination systems of drop transmission and transmission, can observe opaque and transparent samples respectively, and the three-eyepiece tube can switch the polarization observation.

$ 2268.00

Using differential Light spectrum engine and dual light path design, Sensor light intake is increased by 50%, Light spectrum resolution is increased by 30%. The inter-station conformity can reach dE * ab ≤ 0.08, Repeatability accuracy can reach dE * ab ≤ 0.005, and it has four measurement aperture automatic switching and temperature Humidity calculation compensation functions.

$ 22633.00

Using dual array 256 pixel CMOS Detector, measurement Wavelength range 360~ 780nm, support reflection and transmission measurement, four caliber automatic switching, built-in temperature monitoring and compensation, to ensure accurate and stable Color data.

$ 9562.00

With 5000V output voltage and 1000GΩ Measurement range, it supports polarization index testing and USB data transmission, and the backlit display is easy to read measurement results in dark environments.

$ 310.00

Measurement principle of diffuse transmission, optical density Measurement range of 6.000 OD, accuracy +/- 0.02 OD, equipped with fixed seat and bracket, support two Measurement mode, suitable for translucent material testing.

$ 743.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Transmittance Tester Measures the Clarity of Optical Films
This article introduces how to use a transmittance tester to measure the clarity of optical films. Clarity refers to the fidelity of imaging after light passes through the film. The tester is based on the principle of light transmission, calculating the clarity value using a formula by measuring the intensity of parallel transmitted light and scattered light.
Haze meter measures light transmission and scattering in agricultural film.
This article introduces how a haze meter measures the light transmittance and the proportion of scattered light in agricultural films. Haze is the percentage of scattered light in the total transmitted light, while light transmittance is the ratio of transmitted light to incident light.
Which is more accurate for measurement: the scattering method or the transmission method in turbidimeters?
The article compares two methods for measuring turbidity: the scattering method and the transmission method. The choice of method depends on the turbidity range of the sample, particle characteristics, and measurement standards. Both methods have their respective applicable scenarios, and accuracy depends on the actual application conditions.
The laboratory film applicator provides a uniform coating solution for the preparation of optical thin films.
The quality of optical thin film preparation directly affects the performance of optical components, such as transmittance, reflectivity, and durability. Laboratory coating machines, through precise control of the coating process, provide critical support for the research, development, and small-scale production of optical thin films.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.