Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.
8L Tank Volume, Temperature range -25~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, equipped with maintenance-free pump to achieve horizontal and vertical mixing, support internal and external circulation and multiple safety protection.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices including low water level protection and temperature runaway alarm functions.
Vertical double air duct vertical hot air circulation design, high temperature uniformity, temperature control accuracy of +/- 1.0 ℃, studio volume 30L, equipped with turbine centrifugal fan blades and low noise blower, fan speed regulation, easy operation and maintenance.
Temperature control accuracy of +/- 0.3 ℃, support for the installation of a variety of folding fixture, suitable for different materials in low temperature environment folding performance test.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ° C. Safety protection devices include low water level anti-dry burning and Compressor overcurrent protection to ensure safe and reliable operation.
Vertical design with bottom drum and bottom heater, turbine centrifugal fan blade to achieve vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, studio volume 125L, PID microcomputer intelligent temperature control to ensure uniform and stable temperature.
8L Tank volume, Temperature range -35~ 100 ℃, equipped with maintenance-free pressure pump to achieve two-way mixing, support single point and two point temperature calibrating, with low level protection and buzzer sound and light alarm function.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ° C. Safety protection devices include low water level anti-dry burning and Compressor overcurrent protection to ensure stable operation of the equipment.
Adopt non-heat centrifugal circulation pump to avoid its own heat generation affecting the temperature field, equipped with High Accuracy PT100 Sensor to achieve 0.01 ℃ resolution. With low water level protection, Compressor multiple protection and other safety functions, the liner is made of S304 stainless steel.
With vertical oscillation mode, Oscillation Frequency up to 280rpm, pendulum amplitude of 20mm, smooth operation and low noise, stepless speed regulation can be flexibly adjusted, stainless steel spring fixture is suitable for a variety of test bottles.
Using non-fluorine environmental protection Compressor refrigeration system, Temperature Uniformity up to +/- 0.05 ℃, equipped with High Accuracy PT100 Sensor and centrifugal circulation pump, to avoid self-heating affecting the temperature field, to ensure accurate and stable temperature control.
Adopt vertical double air duct vertical hot air circulation, temperature control accuracy +/- 1.0 ℃, Temperature resolution 0.1 ℃, with timing and over-temperature alarm function, turbine centrifugal fan blade with bottom drum and bottom heating to ensure Temperature uniformity.
Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.
Using non-fluorine Compressor refrigeration system, Temperature Uniformity up to +/- 0.05 ℃, equipped with High Accuracy PT100 Sensor and centrifugal circulation pump, to avoid its own heat affecting the temperature field, support multi-stage program temperature control.