Digital Infrared Thermal Imaging Camera

Digital infrared thermal imagers receive infrared radiation emitted from the surface of objects, convert it into electrical signals, and process it into temperature distribution images. They are used to detect abnormal surface temperatures of materials, monitor thermal distribution during production processes, and are applied in equipment maintenance, quality inspection, and energy consumption analysis.
Selection
When selecting, consider the temperature range and size of the detection target to match the instrument's resolution and temperature measurement accuracy. Pay attention to the thermal sensitivity parameter to ensure the ability to detect subtle temperature differences. Determine the protection level based on the usage environment; for outdoor use, dustproof and waterproof features are required. Ensure the interface type is compatible with existing equipment, and the analysis software functions meet basic needs.

Terms

Standards

Instruments

Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.

$ 149.00

Using vanadium oxidation uncooled infrared focal plane Detector, temperature resolution of 0.1 ℃, with 56 ° × 42.2 ° field of view and focus-free design, support center point temperature measurement and cold hot spot automatic tracking function.

$ 428.00

Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.

$ 5850.00

Equipped with Infrared Sensor and Thermal Probe Dual Measurement mode, Response Time is only 1 second, Optical inspection coefficient is 3:1, support -40~ 150 ℃ wide range temperature measurement, to meet the needs of accurate temperature detection in different scenarios.

$ 654.00

Built-in mobile slide table can move the camera front and rear, high display finger no stroboscopic LED Illuminant Color temperature is stable, the illuminance is adjustable, the back plate of the box can post 712mm * 400mm test card to provide a uniform lighting environment.

$ 4592.00

High-resolution digital camera to achieve automatic detection, can simultaneously measure five capillary tubing, temperature range RT +~ 400 ℃, with automatic measurement and manual visual measurement function, support multi-point calibrating and data export.

$ 4874.00

With 260 * 200 thermal imagery resolution and 70mK thermal Sensitivity, it can quickly locate the abnormal temperature rise point of the circuit board, support -10~ 120 ℃ temperature measurement range, equipped with adjustable lens and multi-directional adjustment bracket, easy to accurately observe the thermal distribution of the circuit board.

$ 1022.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with stainless steel liner, rapid and uniform heating, suitable for drying a variety of samples.

$ 690.00

Color temperature adjustment range 2300K-8000K, illumination adjustment range 0-4000Lux, built-in mobile slide can move the camera front and rear, light source light board can swirl/spin to adjust the angle, provide a uniform lighting environment.

$ 5366.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor temperature control, fast low consumption, suitable for a variety of sample drying.

$ 756.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast drying, low energy consumption and easy adjustment, suitable for a variety of Sample Handling.

$ 581.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, fast and low consumption, equipped with thermistor temperature control, the studio is made of 304 stainless steel, size 750 * 600 * 600mm, easy to adjust, suitable for drying treatment of various samples.

$ 840.00

Temperature range -40 ℃ to + 150 ℃, the temperature conversion time is only 10 seconds, using PID full digital automatic Control system, can quickly detect the material in the extremely high temperature and low temperature continuous environment resistance and thermal expansion and contraction changes.

$ 17303.00

Suitable for soft rubber, thermal plasticity resilience and extremely soft plastics, Hardness Measurement range < 20 HDO, with real-time, peak, timing and average Measurement mode, can be connected to the computer for data management and analysis.

$ 590.00

With camera viewing function to prevent measurement deviation, Repeatability Standard Deviation Delta E * ab within 0.05, dual Measurement mode synchronously displays SCI and SCE results, large storage space can store 20,000 data.

$ 3543.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.