Four-Channel Furnace Temperature Meter

The four-channel furnace temperature tester simultaneously collects temperatures from different locations inside the furnace using four thermocouples, converting the thermoelectric potential into digital signals for recording. It is used to monitor temperature distribution during processes such as baking and curing, and to verify that the actual temperature curves meet process requirements during coating curing and plastic processing.
Selection
When selecting, ensure the temperature measurement range covers the process requirements, the number of channels matches the monitoring points, and the sampling rate meets the requirements for recording changes. Pay attention to the compatibility of the thermocouple type with the operating environment, the device's protection level aligning with on-site conditions, and the data analysis software's functionality meeting the requirements for record traceability.

Terms

Instruments

Four-channel configuration with K-type Thermocouple, the sampling rate can be adjusted from 1 second to 1 minute, and the thermal insulation performance can last for 60 minutes in a 500 ° C environment to achieve full temperature tracking monitoring.

$ 1014.00

Four-channel K-type Thermocouple with 0.5% accuracy, the insulation box can work continuously for 1 hour in a 300 degree environment, supports multi-rate sampling and 16000 Data storage, Stability is high and easy to operate.

$ 624.00

Four-channel synchronous acquisition, supports a variety of Thermocouple types, the temperature measurement range covers -200 to 1800 ° C, with broken couple detection function and upper and lower limit alarm settings, Fast Response and stable data.

$ 294.00

Four-channel K-type Thermocouple configuration, accuracy of 0.5%, insulation performance maintained at 400 ℃ for 60 minutes, support multi-rate sampling and data synchronization analysis, to ensure stable and reliable temperature mapping.

$ 940.00

With 9-channel K Probe, Sampling rate of 0.05 seconds, Measurement range -200 to 1370 ℃, superior thermal insulation performance, can track and monitor Furnace temperature and pRoduct temperature throughout the process in harsh thermal environments.

$ 1669.00

With 6-channel temperature recording capability, thermal insulation performance can reach 400 ° C for 60 minutes, Measurement range -200-1370 ° C, accuracy +/- 0.3 ° C, using nano-aerospace environmentally friendly thermal insulation materials, support multi-directional temperature Linear dispersion tracking mapping.

$ 1305.00

6 channel temperature recording, 700 ℃ environment can work for 90 minutes, using nano aerospace environmental protection insulation material, support 1-30 seconds adjustable Sampling rate, real-time tracking Furnace temperature Linear dispersion, to ensure the stability of the brazing mass.

$ 3372.00

The six-channel design supports multi-position simultaneous temperature measurement, Sampling rate of 0.05 seconds, with 512M memory can store 16 consecutive test data, and the heat insulation box works stably for 10 minutes in a 280 ° C environment to ensure the accuracy of high temperature scene data.

$ 1427.00

Linear dispersion of temperature up to 16 points can be obtained at a time, supports wireless real-time synchronization recording data, and adopts USB communication port, which can be used for 50 hours after being fully charged, and is easy to operate.

$ 2139.00

The maximum temperature is 1200 ℃, the Furnace volume is 2L, the microcomputer PID controller is used for precise temperature control, the door sealing design enhances Temperature uniformity, and the corrosion resistance refractory brick Furnace is durable.

$ 838.00

The maximum temperature is 1000 ℃, the Furnace volume is 30L, the 30-segment programmable controller is used to realize automatic operation, the Furnace door sealing is good to ensure Temperature uniformity, the refractory brick Furnace and the resistance wire heating element are resistant to high temperature and have a long life.

$ 1815.00

With 30 programmable control function, support heating or stay setting, stainless steel Furnace door and microcomputer PID controller, to ensure accurate and reliable temperature control, Furnace Temperature uniformity.

$ 1313.00

Supports 16-channel simultaneous temperature measurement, uses K-type Thermocouple to achieve +/- 1 ° C accuracy, has wireless real-time transmission function, can store 16 sets of data and export Excel reports, and intelligently save data when powered off.

$ 1929.00

The highest temperature up to 1000 ℃, Furnace volume 16L, the use of refractory brick Furnace and wirecoil for heater heating, with automatic safety switch and overheating and overpressure protection, Furnace door sealing good heat loss is small.

$ 1145.00

8-Channel design supports multi-point simultaneous temperature measurement, using nano-space insulation material to ensure stable operation at 300 ℃ environment for 60 minutes, equipped with K-type Thermocouple to achieve +/- 0.3 ℃ High Accuracy measurement, suitable for high temperature process monitoring.

$ 1390.00