Heavy-duty stainless steel structure ensures stable support, equipped with 3 strong magnets for firm adsorption, maintaining the vertical state of Microscope, suitable for various metal surface fixing needs.
Provides 40x magnification and a 0.60 numerical aperture to ensure high resolution and long working distances for a variety of Microscope applications.
Made of aluminum, Dimension 150 * 220 * 290mm, support 360 ° swirl/spin adjustment and arm adjustable, suitable for a variety of Microscope models.
Support capillary tubing and hot stage two measurement methods, temperature range RT +~ 320 ℃, Microscope 40 times magnification observation, sexual repeability +/- 1 ℃ (≤ 200 ℃), to meet the melting point of crystalline organic compounds determination needs.
Using fluorine-free refrigeration system and mirror stainless steel liner, temperature range -40~ 65 ℃, with microcomputer intelligent control and independent temperature limit alarm function, support multi-stage programming and RS-485 communication interface.
Low-contrast samples can be observed by using phase contrast microscopy, equipped with 10X-100X phase contrast objective lens and N.A.1.25 condenser lens, and supports coarse fretting coaxial focusing mechanism to fine-tune the grid value of 0.002mm.
Microscope observation mode, support capillary method and hot table method, temperature range RT +~ 320 ℃, resolution 0.1 ℃, repeability +/- 1 ℃ (≤ 200 ℃), Draft Shield design to reduce environmental impact.
Using binocular stereo Microscope observation, support capillary method and hot table method two measurement methods, temperature resolution of 0.1 ℃, repeability +/- 1 ℃ (≤ 200 ℃), with Draft Shield to reduce environmental impact.
Using 1 inch full frame size 6.10 million pixel sensor, supports fluorescence mode 6 high-speed shots per second, with extremely low noise point and 69.8dB dynamic range, semiconductor cooling ensures stable operation.
Can achieve -80 ℃ low temperature control, built-in two-stage magnetic stirring system, Speed range 100-1200RPM, equipped with high temperature and over-temperature protection functions, environmentally friendly refrigerant to ensure safe operation.
Equipped with 0.7-4 times high definition industrial grade continuous zoom Microscope, the three-dimensional movement accuracy of the stage reaches 0.01mm, supports video recording and automatic titration function, can observe and test from multiple angles, and data export is convenient.
Adopt two-stage Compressor cascade refrigeration technology implementation -40 ℃ low temperature, PID temperature control with proportional refrigeration technology to improve the temperature Stability to +/- 0.5 ℃, DC brushless motor supports 100-1200RPM stepless speed regulation, with a variety of alarm and automatic recovery function.
Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.
Adopt two-stage Compressor cascade refrigeration technology implementation -40 ℃ low temperature, equipped with PID temperature control technology to ensure Temperature Stability +/- 0.5 ℃, DC brushless motor supports 100-1200rpm stepless speed regulation, with automatic alarm and power failure recovery function.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.