Oil and water Tank coating Gloss Meter

The gloss meter for oil and water tank coatings projects light onto the coating surface at a fixed angle and calculates the gloss value by detecting the intensity of the reflected light. It is used to quantify the surface light reflection capability of protective coatings for oil and water tanks, monitoring the consistency of coating appearance in ship and storage tank anti-corrosion projects.
Selection
When selecting, consider matching the measurement angle to the coating gloss range: use 20° for high gloss, 60° for medium gloss, and 85° for low gloss. The instrument must comply with ISO 2813 standards, feature a probe resistant to solvent corrosion, and include temperature compensation. Verify that the measurement range covers 0-200 GU, with a repeatability error of ≤0.2 GU.

Terms

Standards

Instruments

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, Temperature control accuracy 0.01 ℃, Built-in High Accuracy PT100 Sensor, support external circulation and domestic circulation system, ensure that the flow field and temperature field in the Tank are highly uniform.

$ 869.00

Water and oil dual-use supports room temperature to 100 ° C, capacity 5L, Temperature Uniformity +/- 0.05 ° C, with domestic circulation system to avoid heat effects, external circulation to establish a second thermostatic field, Safety protection includes power failure and low water level alarm.

$ 435.00

With dual-use function of water and oil, Temperature Uniformity up to +/- 0.05 ℃, Flow rate of external circulation pump 6L/min, liner with S304 stainless steel, Safety protection including power failure and low water level alarm.

$ 816.00

The equipment has a 15-liter large-capacity water Tank and an 8mm inner diaMeter water pipe, supports 0 to 99 hours of time control, adopts stainless steel structure and automatic control device, and is suitable for coating stain resistance testing.

$ 369.00

With water and oil dual-use function, Temperature Uniformity +/- 0.05 ℃, Temperature range from room temperature to 200 ℃, domestic circulation system adopts no heat centrifugal pump to avoid affecting the temperature field, support external circulation to establish a second thermostatic field.

$ 924.00

Water and oil dual-use optional room temperature to 100 ℃ range, external circulation function to establish a second thermostatic field, Temperature Uniformity +/- 0.05 ℃, domestic circulation without heat centrifugal pump to avoid the impact of temperature field, Safety protection including power failure and low water level alarm.

$ 1058.00

Water and oil dual-use Temperature range Room temperature to 200 ℃, Temperature Uniformity +/- 0.05 ℃, with internal and external circulation system and multiple Safety protection, the use of heat-free centrifugal pump to avoid affecting the temperature field uniformity.

$ 761.00

Water-oil dual-use design, Temperature Uniformity up to +/- 0.05 ℃, support external circulation function, Pump Flow rate 6L/min, with multi-Safety protection and optional program temperature control.

$ 562.00

The equipment supports water and oil dual-use, Temperature range from room temperature to 300 ℃, capacity 40L, using PID automatic temperature control and High Accuracy PT100 Sensor to ensure stable and uniform temperature, with domestic circulation system to avoid heat impact, Safety protection function is complete.

$ 1148.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, no heat centrifugal circulation pump and domestic circulation system, to ensure temperature stability and flow field uniformity, support a variety of Safety protection.

$ 559.00

With water-oil dual-use function, Temperature Uniformity +/- 0.05 ℃, built-in High Accuracy PT100 Sensor, support for external circulation to establish a second thermostatic field, optional program temperature control and Communication interface.

$ 1048.00

With water and oil dual-use function, Temperature Uniformity +/- 0.05 ℃, Temperature range to 100 ℃, External circulation pump Flow rate 6L/min, Built-in Safety protection and optional program temperature control, suitable for a variety of experimental needs.

$ 1416.00

With 0.0001 ℃ high digital resolution, Temperature Uniformity +/- 0.005 ℃, support water-oil dual-use Temperature range, built-in Safety protection function to ensure stable and reliable operation.

$ 1237.00

Water and oil dual-use Temperature range, domestic circulation system with no heat centrifugal pump, Temperature Uniformity +/- 0.05 ℃, with multi-level Safety protection and optional program temperature control function.

$ 672.00

Temperature resolution of 0.0001 ℃, Fluctuation +/- 0.005~ 0.01 ℃, the use of heat-free centrifugal circulation pump to ensure uniform insulation field, support water and oil dual-use and a variety of Safety protection functions.

$ 2402.00

Articles

Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Gloss meter measures the gloss consistency of resin coating film surfaces.
This article introduces how to use a gloss meter to measure the gloss consistency of resin coating film surfaces.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Glossmeter 75-degree angle measurement for paper gloss
This article introduces the principle and method of measuring paper gloss using a 75-degree specular gloss meter. Gloss is defined as the ratio of the light reflected from the paper surface to that reflected from a standard reference plate, with the 75-degree angle commonly used for measuring medium to high gloss papers.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
Method for measuring the gloss of ink surfaces using a gloss meter
This article introduces the method of measuring the surface gloss of ink using a gloss meter. Gloss is a key indicator of the visual quality of ink, and the instrument quantifies gloss by measuring reflected light at specific angles.
The use of a gloss meter in evaluating the surface gloss of printing paper and art paper.
Gloss meters quantify paper gloss by measuring surface reflected light, with 20°, 60°, and 85° angles commonly used for high, medium, and low gloss surfaces, respectively. The gloss characteristics of printing paper and art paper differ, so the appropriate measurement angle should be selected based on the estimated gloss level.
Determination of specular gloss: Selection criteria for instruments at different angles (20°/60°/85°)
Specular gloss is a measure of a material's ability to reflect light, calculated by comparing the reflected luminous flux of a sample with that of a standard plate. Three angles—20°, 60°, and 85°—are commonly used for measurement, corresponding to high-gloss, medium-gloss, and low-gloss surfaces, respectively.