Electrically Heated Incubator

Electric incubators maintain a constant internal temperature through heating elements and a temperature control system. They are used in experimental processes that require stable temperature environments, such as sample drying, material aging tests, and bacterial cultivation.
Selection
When selecting, consider that the temperature range must cover experimental requirements, uniformity affects the consistency of sample heating, and capacity is determined based on sample size. Pay attention to indicators such as heating rate and temperature control accuracy, and ensure the material's corrosion resistance is suitable for the operating environment.

Terms

Standards

Instruments

Temperature range RT + 5~ 99 ℃, Temperature Fluctuation +/- 0.5 ℃, stainless steel liner, beaker hole can be arbitrarily changed in size, over-temperature sound and light tracking alarm to protect the sample.

$ 317.00

Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.

$ 1427.00

Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.

$ 2315.00

Temperature control accuracy +/- 0.3 ℃, resolution 0.1 ℃, mirror stainless steel liner for easy cleaning, silicone sealing ring to ensure high sealing, microcomputer controller provides stable and reliable operation.

$ 658.00

Using stainless steel liner, beaker hole can be arbitrarily changed size, temperature control accuracy +/- 0.5 ℃, with over-temperature sound and light tracking alarm function to ensure the safety and reliability of the sample.

$ 275.00

Temperature control accuracy of +/- 0.5 ℃, Temperature resolution of 0.1 ℃, with over-temperature sound and light alarm function, stainless steel liner can adapt to different beaker sizes, support internal and external circulation, ensure sample safety and stability.

$ 244.00

Fuzzy PID controller is used to control temperature with accurate fluctuation, Temperature Uniformity +/- 1.5 ℃, Forced convection air duct to improve Response speed, Mirror stainless steel liner is heated evenly, and independent temperature limit alarm system ensures safety.

$ 430.00

Microcomputer controller to achieve 0.1 ℃ resolution temperature control, mirror stainless steel liner easy to clean, equipped with silicone sealing ring to ensure the high sealing of the studio, over-temperature alarm function to improve the use of safety.

$ 362.00

Water-Jacketed heating is used to ensure uniform temperature, and it can still be thermostatic for a long time after power failure; the circulating wind speed is automatically adjusted to avoid sample volatilization; it has multiple Safety protection functions such as temperature, water level and door opening alarm.

$ 772.00

Mirror stainless steel liner for easy cleaning, Temperature range 5 ℃~ 65 ℃ and Fluctuation +/- 0.3 ℃, microcomputer controller to ensure stable and reliable temperature, silicone sealing ring to ensure high sealing.

$ 535.00

Equipped with a heated vacuum bed, the temperature can reach 100 ° C, the coating speed range is 0.1~ 500mm/s, Travel 415mm, supports a variety of film tools, and the intelligent interface simplifies the operation.

$ 22118.00

The microcomputer controller is used to achieve accurate temperature control, Fluctuation is only +/- 0.3 ℃, Mirror stainless steel liner is easy to clean, Silicone sealing ring ensures high sealing of the studio, liner size 400 × 400 × 500mm.

$ 435.00

Water-Jacketed heating is used to ensure uniform and stable temperature, and it can still maintain thermostatic for a long time after power failure; the circulating wind speed is automatically adjusted to avoid sample volatilization; multi-stage programmable control realizes temperature layer change, and supports 0~ 9999 minutes timing.

$ 1519.00

Equipped with perforated heated vacuum bed, the temperature can be increased to 100 ° C, the coating speed range is 0.1-500 mm/s, and the bar and Blade Coating methods are supported to ensure uniform film thickness and sample repeatability.

$ 22118.00

The annular halogen heater is used to ensure that the sample is uniformly heated and the surface is not damaged, and it only takes 4-5 minutes to dry quickly. Moisture measurement range is 0.00% -100.00%, readable accuracy is 0.10%, temperature adjustable 40-199 ° C and historical data printing function are supported.

$ 557.00