Particle Fineness Detector

The particle fineness detector measures the particle size distribution in samples through light scattering or sedimentation methods. It is used in industries such as coatings and inks to control product uniformity and ensure production meets specification requirements.
Selection
When selecting, consider that the measurement range should cover the particle size of the samples, employ techniques such as laser diffraction or dynamic light scattering, focus on repeatability and ease of operation, and align with industry-standard testing requirements.

Terms

Standards

Instruments

Made of stainless steel, the range is 0-100μm, Graduation is 5μm, and the plane flatness of the scraper is 0.003mm to ensure accurate and reliable particle fineness measurement.

$ 138.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-25μm, ergonomic design, easy to hold, suitable for particle size and fineness of grinding detection.

$ 1157.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-250μm, ergonomic design for easy holding, suitable for particle size and fineness of grinding inspection.

$ 1531.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-100μm, suitable for particle size and fineness of grinding inspection, ergonomic design for easy grip.

$ 1157.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-15μm, ergonomic design, easy to hold, suitable for particle size and fineness of grinding detection.

$ 1157.00

Made of Hardness 52 +/- 2HRC wear and corrosion resistant alloy steel with 0-100μm range and 5μm Graduation, the single-channe design meets several international standards for a wide range of material particle Fineness measurement.

$ 172.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-50μm, ergonomic design for easy holding, suitable for particle size and fineness of grinding inspection.

$ 1157.00

1400 rpm high-speed stirring is used to achieve strong tensile shear and Impact between the material and the sand, the fineness of grinding can reach 25 microns or less, and the capacity is 1.5 liters, which is suitable for laboratory sample dispersion grinding.

$ 619.00

Made of stainless steel, with a range of 50 to 150 μm and a Graduation of 10 μm, the plane finish of the scraper is up to 10 grades, suitable for accurate determination of particle fineness in the Coating and inks industries.

$ 138.00

Made of hardened stainless steel with an accuracy of 2μm, with a range of 0 to 5000μm and a groove length of 120mm, to ensure the accuracy and durability of particle size measurement.

$ 2442.00

Made of hardened stainless steel, with an accuracy of 2 μm, equipped with a double groove design, supports a range of 0-5000 μm, and is suitable for particle size determination of various materials.

$ 1886.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-500μm, ergonomic design for easy holding, suitable for particle size detection.

$ 1714.00

Made of hardened stainless steel with accuracy up to 2μm, with double groove design, supports three Measurement units of μm, NS and PCU, suitable for particle size determination of various materials.

$ 2420.00

The kit can realize automatic grinding fineness Gauge operation, improve test Repeatability, suitable for standard scraper fineness Meter supporting use, simplify the experimental process.

$ 1623.00

Measurement range 0.5-3000 μm, maximum resolution 0.1μm, support more than 30 image analysis functions, Particle size distribution and morphology analysis.

$ 5237.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
Blue-style grinder achieves efficient grinding of ink fineness.
The basket mill is a type of wet grinding equipment used in fine chemical fields such as ink production. It utilizes a high-speed rotating impeller to drive grinding media, generating shear and impact forces on the slurry, thereby dispersing pigment particles and reducing their fineness.
Application of High-Speed Disperser in the Preparation of Water-Based Inks
This article introduces the application of a high-speed disperser in the preparation of water-based inks. It first explains the working principle of the equipment, which involves generating shear forces through high-speed rotation to disperse particles.
Ink fineness gauge measures the dispersion degree of pigment particles.
The fineness of grind gauge is a method used to evaluate the dispersion level of pigment particles in ink.
Which is more accurate for measurement: the scattering method or the transmission method in turbidimeters?
The article compares two methods for measuring turbidity: the scattering method and the transmission method. The choice of method depends on the turbidity range of the sample, particle characteristics, and measurement standards. Both methods have their respective applicable scenarios, and accuracy depends on the actual application conditions.
Core Differences and Selection Guide for Pulpers and Refiners
Both the beater and the refiner are equipment for processing materials, but their core functions differ. When selecting the appropriate machine, it should be based on the characteristics of the material: choose a beater for fiber treatment and a refiner for particle refinement, while also taking into account process requirements and operational costs.
Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Porosity Control in the Preparation of Porous Coatings During the Blade Coating Process
Doctor blade coating is a wet coating technique widely used for preparing functional coatings, which involves uniformly applying a slurry containing solid particles (such as ceramics, polymers, or metal oxides) onto a substrate, followed by drying and heat treatment to form the coating.
The main issue with using a Ubbelohde viscometer is that 90% of capillary blockages are caused by inadequate sample filtration.
More than 90% of capillary blockage in Ubbelohde viscometers during measurement is due to inadequate sample filtration. Minute particles or gels in the sample tend to adhere to or become trapped when flowing through the narrow capillary, leading to abnormal flow rates and affecting measurement accuracy.
An article tells you how to choose a fineness gauge.
This article introduces how to select and use a grind gauge. It is a tool for measuring particle size in coatings and inks. When selecting one, the first step is to choose the appropriate range based on the estimated fineness of the sample (commonly 0-50 µm or 0-100 µm).