Heat Sealer for Packaging Bags

The packaging bag heat sealer applies temperature and pressure to the film through upper and lower heating plates, causing the surface layers of the material to melt and bond. It is used to test the sealing strength of soft packaging for food, pharmaceuticals, and other products, simulating the actual production line sealing effect to ensure a leak-free seal.
Selection
When selecting, ensure the film material matches the temperature range, pressure adjustment must cover 20-600N, and the heat sealing time is precise to 0.1 seconds. The flatness error of the working plate is less than 0.05mm, and it is equipped with anti-scald design and pneumatic stabilization system.

Instruments

The heat sealing paraMeters were determined by hot-pressing sealing method, the temperature control accuracy was +/- 1 ℃, the heat sealing time was adjustable 0.1-999 s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured the safety of use.

$ 1200.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, heat sealing time 0.1~ 999.9s adjustable, heat head with brass material to ensure uniform heat conduction, double-decked thermal insulation protection to ensure safe operation.

$ 3015.00

The heat sealing performance was determined by hot pressing sealing method, the temperature control accuracy was +/- 0.2 ℃, the heat sealing time was 0.1~ 999.9s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured safety.

$ 1603.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, independent temperature control of upper and lower heat sealing heads, good thermal conduction effect of brass heat sealing knife, double-decked thermal insulation design to ensure safe use.

$ 1764.00

Adopt double cylinder synchronous circuit and upper and lower heat seal independent temperature control, Heat seal Temperature range RT +~ 300 ℃, Temperature control accuracy +/- 1 ℃, support manual and pedal two start modes, heating head with protective cover to ensure safety.

$ 1300.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, double-decked thermal insulation design to effectively prevent burns, support manual and pedal two start mode.

$ 1361.00

Adopt digital P.I.D. temperature control, upper and lower heat seal independent temperature control, heat sealing temperature range RT +~ 300 ℃, heat sealing pressure 0.05~ 0.7MPa, support manual and foot pedal start mode, anti-burn safety design.

$ 1413.00

Adopt digital P.I.D. temperature control, temperature control accuracy +/- 1 ℃, heat sealing pressure 0~ 0.7Mpa adjustable, double cylinder structure to ensure pressure equilibrating, heat sealing knife aluminum alloy material uniform heat conduction, support automatic and manual mode.

$ 1663.00

Digital P.I.D. temperature control, temperature control accuracy +/- 1 ℃, heat sealing temperature up to 300 ℃; dual cylinder structure to ensure pressure equilibrating, heat cover temperature uniformity, support automatic and manual operation mode, improve test efficiency.

$ 1461.00

The heat sealing paraMeters are determined by hot pressing sealing method, the temperature control accuracy is +/- 0.1 ℃, the heat sealing temperature can reach 300 ℃, and the upper and lower heat sealing heads have independent temperature control and manual foot pedal dual start mode, which is safe and anti-scalding design.

$ 2110.00

The heat sealing paraMeters are tested by hot pressing sealing method, the temperature control accuracy is up to +/- 0.2 ℃, the heat sealing time is adjustable from 0.1 to 999.9s, and the upper and lower heat sealing heads are supported for independent temperature control and a variety of heat cover customization to ensure accurate and reliable test data.

$ 2494.00

With 30 +/- 2mm amplitude and 2-3Hz vibration Frequency, it can simulate the long-term vibration environment of portable plastic bags, support 20KG load-bearing and 99999 counts, and meet the standard test requirements.

$ 2263.00

Digital PID Temperature Control system, temperature control accuracy of +/- 0.2 ℃, the upper and lower heat head independent temperature control, double cylinder synchronous circuit to ensure pressure Balance, heat cover heating uniform, support manual and foot pedal dual operation mode.

$ 1656.00

Using transient planar heat source technology, the test time is adjustable from 5 to 160 seconds, the accuracy is +/- 3%, it supports nondestructive detection, no special sample preparation is required, and it is suitable for a variety of physical materials.

$ 5076.00

Six sets of independent digital PID temperature control system to achieve +/- 1 ℃ temperature control accuracy, dual cylinder design to ensure uniform pressure at both ends, Heat Seal Temperature range RT +~ 260 ℃, support layer setting can simultaneously test five sets of different paraMeter samples.

$ 2268.00