Oxidation High-Low Temperature Test Chamber

The oxidation high-low temperature test chamber simulates temperature change conditions that materials undergo in an oxygen-containing environment through its heating, cooling, and oxygen supply systems. It is used to observe the aging, cracking, or performance changes of samples under oxidation and temperature cycling, commonly employed in durability testing of materials such as plastics and coatings.
Selection
When selecting, consider that the temperature range should cover the actual usage environment, the chamber size should accommodate the sample dimensions, the temperature control accuracy should meet testing requirements, the oxygen concentration should be adjustable, the equipment materials should be corrosion-resistant, the operation interface should be user-friendly, maintenance should be convenient, and energy consumption should be reasonable.

Terms

Standards

Instruments

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.

$ 8497.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 6254.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.

$ 6431.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and aging test, in line with a number of national standards.

$ 6770.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 5947.00

With inert gas protection system to prevent oxidation and decarburization of heating workpiece, rated temperature 1200 ℃, Inner Chamber dimensions 300 * 200 * 120mm, suitable for a variety of high temperature heat treatment applications.

$ 659.00

With inert gas protection function, it can prevent high temperature heating workpiece oxidation decarburization, rated temperature 1000 ℃, Inner Chamber dimensions 200 * 120 * 80mm, shell made of cold plate and steel and high temperature spray.

$ 507.00

Temperature range -60~ 150 ℃, studio volume 1000L, stainless steel studio and high temperature insulation material, support high and low temperature cycle change test, in line with a number of national standards.

$ 9352.00

Temperature range -40~ 150 ℃, studio volume 150L, suitable for high temperature and low temperature Reliability test, in line with a number of national standards, aging test and constant temperature test.

$ 5431.00

Temperature range -70~ 150 ℃, studio volume 80L, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature cycle change test, support aging test and a variety of standard requirements.

$ 5560.00

Adopting a specific process equipped with air inlet and outlet device, inert gas can be intRoduced to achieve high temperature heating and oxidation prevention, Inner Chamber dimensions 500 * 300 * 200mm, rated temperature up to 1000 ℃, the shell is made of cold plate and section steel and sprayed at high temperature.

$ 877.00

Temperature range -20~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature cycle change test, suitable for aging test and material performance inspection.

$ 7109.00

Temperature range -20~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature, low temperature and constant temperature test, suitable for Reliability test, equipped with multiple protection devices and safety system.

$ 4818.00

The equipment is equipped with an inlet and outlet device, which can pass inert gas to achieve anti-oxidation decarburization at a high temperature of 1000 ° C. Inner Chamber dimensions are 400 * 250 * 160mm, suitable for high temperature sintering and quenching and other heat treatment applications.

$ 691.00

Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.

$ 3301.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
High Performance Liquid Chromatography for the Detection of Additives in Ink
This article introduces the use of high-performance liquid chromatography (HPLC) to detect additives in ink. Additives such as photoinitiators and antioxidants affect the performance and safety of ink, making accurate detection crucial.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Copper nanowire and zinc oxide thin film preparation coater
The coating machine is a key device for preparing copper nanowires and zinc oxide thin films, which uniformly coats slurry onto a substrate through methods such as blade coating to form a thin film.