Liquid Low Temperature Thermostatic Bath

The liquid low-temperature thermostatic bath maintains the liquid inside at a set low temperature and keeps it constant through the coordination of a refrigeration system and a heater. It is used for sample cooling, material testing, and other applications, providing a stable low-temperature environment for experiments such as paint curing and ink viscosity testing.
Selection
When selecting, consider that the temperature range should cover experimental needs, the temperature control accuracy should match testing standards, the tank capacity should accommodate sample sizes, and the cooling power should ensure the required cooling rate. Additionally, pay attention to the corrosion resistance of the tank material, the availability of safety protection features, and the convenience of daily maintenance.

Terms

Standards

Instruments

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, equipped with 6 liter Tank and 8L/min Pump Flow rate, support liquid level alarm and computer communication, the inner Tank and the box are made of high quality stainless steel.

$ 1108.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to meet diverse experimental needs.

$ 942.00

Using non-fluorine environmental protection Compressor refrigeration, temperature fluctuation +/- 0.05 ℃, equipped with High Accuracy PT100 Sensor and domestic circulation pump, to avoid its own heat generation affecting the temperature field uniformity, to ensure stable and reliable temperature control.

$ 861.00

The temperature fluctuation is controlled within +/- 0.05 ℃, the non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field, and multiple Safety protection devices are equipped to ensure stable and reliable operation.

$ 1237.00

The non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ℃. Safety protection devices are equipped to ensure stable operation of the equipment and support external circulation functions to meet diverse experimental needs.

$ 1611.00

The double Compressor cascade refrigeration system is adopted, which has high refrigeration efficiency and low noise; the overall foaming and heat insulation of the Tank body reduces the loss of cooling capacity; Temperature Fluctuation +/- 0.05 ℃, Pump Flow rate 10L/min to ensure the uniformity of liquid in the Tank.

$ 2897.00

Microcomputer thermostatic Control system, Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, two-way communication and liquid level alarm function, Pump Flow rate 10L/min.

$ 1889.00

The double Compressor cascade refrigeration system is adopted to ensure rapid cooling, and the overall foaming process of the low temperature Tank body reduces the loss of cooling capacity. Temperature Fluctuation +/- 0.05 ℃, Pump Flow rate 10L/min ensure the uniformity of liquid in the Tank.

$ 3414.00

Microcomputer thermostatic Control system, Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, two-way communication, equipped with liquid level alarm and 6 liters stirring pump capacity 8L/min.

$ 1206.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, the temperature fluctuation is +/- 0.05 ℃, and it has low water level protection and Compressor multiple protection functions to ensure the safety and stability of the experiment.

$ 1067.00

It adopts transparent carbonic acid ester Bath design, with a volume of 6L, equipped with pressure/suction pump and Pt100 temperature sensor, with low liquid level protection and hardware over-temperature protection functions, and supports external circulation temperature control.

$ 1519.00

The non-heat centrifugal circulating pump is used to ensure uniform insulation field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices such as low water level anti-dry burning and Compressor overcurrent protection, optional temperature control and external Sensor to enhance application flexibility.

$ 4482.00

Double Compressor refrigeration system is adopted to ensure rapid cooling, Tank volume 6L, Pump Flow rate 8L/min to ensure liquid uniformity, Temperature Fluctuation is controlled within +/- 0.05 ℃, and the overall foaming process reduces cooling loss.

$ 946.00

The 24-hole design is compatible with the testtube with a diaMeter of less than 12mm, the maximum Operating temperature is 100 ° C, and the electronic ice box and intelligent thermostatic metal Bath module are optional to meet different temperature requirements.

$ 148.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.