Stereoscopic microscope system

The stereoscopic microscope utilizes a dual optical path design to create a stereoscopic vision, enabling the observation of the three-dimensional structure of samples. It is used for detecting coating thickness in paints and inks, analyzing paper fiber distribution, and performing stereoscopic observation and measurement of microscopic objects in laboratory settings.
Selection
Select the appropriate working distance based on the sample size, choose objective lenses of different magnifications according to observation needs, consider whether image acquisition functionality is required and pair it with a corresponding camera, and adapt the lighting method to meet the observation requirements for different material samples.

Terms

Standards

Instruments

Adopt 12 ° angle of sight axis to realize stereoscopic imagery, working distance up to 90mm, support reflected light and transmitted light illumination, total magnification 20X-60X adjustable, equipped with high eye point eyepiece and Glass workbench.

$ 444.00

Optical inspection system with infinity, 40X-1000X magnification range, 5 million pixel CMOS camera and coaxial focusing mechanism for vertical lighting and fluorescent device expansion.

$ 1758.00

Heavy-duty stainless steel structure ensures stable support, equipped with 3 strong magnets for firm adsorption, maintaining the vertical state of Microscope, suitable for various metal surface fixing needs.

$ 339.00

Provides 40x magnification and a 0.60 numerical aperture to ensure high resolution and long working distances for a variety of Microscope applications.

$ 138.00

Optical inspection system with infinity, support 40X-1600X magnification range, with Abbe condenser and coaxial focusing mechanism, can realize high-resolution real-time observation and digital storage function.

$ 1213.00

Infinity Optical inspection system provides high resolution images, equipped with six hole objective converter and N.A.1.1 Abbe condenser, supports autofocus and multiple Observation methods, magnification 40X-1000X.

$ 11660.00

Optical inspection system with infinite distance is adopted, and stress-free long working distance flat-field objective is equipped. The fretting grid value is 2 μ m, and the rotating stage travels 30 mm vertically.

$ 4882.00

Built-in 16 million pixel imagery system and infinity Optical inspection system, equipped with 9.7 inch IPS retina screen and multiple interfaces, support length, angle and other measurement functions, mildew-proof design to adapt to high heat and humidity environment.

$ 4882.00

Infinity Optical inspection system and Modular function design can realize polarization and dark field observation; Coarse fretting coaxial focusing system fretting grid value of 2 μ m, guide column lifting device to adapt to different Film thickness workpiece detection needs.

$ 2252.00

Optical inspection system with infinite distance provides clear imagery; ultra-long working distance concentrating system up to 70mm, supports high culture dish observation; compact and stable main body design, effective vibration protection.

$ 2746.00

Optical inspection system to improve imagery mass, working distance up to 20mm, support a variety of observation methods, magnification 40X-1000X, to meet different experimental needs.

$ 787.00

Optical inspection system with infinity, 40X-1600X amplification range and LED adjustable Illuminant, support 7-inch display real-time observation, hinged lens barrel can be adjusted at multiple angles for easy operation.

$ 480.00

Optical inspection system infinity to ensure good imagery mass, 70mm long working distance condenser to support high culture dish observation, coarse fretting coaxial focusing system fretting grid value of 2μm to achieve accurate focusing.

$ 2946.00

Optical inspection system, working distance up to 70mm, support phase contrast observation and a variety of culture dish adaptation, compact and stable body design to meet the requirements of vibration protection, providing clear microscopic imagery effect.

$ 3653.00

Optical inspection system with infinity, long working distance objective lens such as 10X0.25 working distance 4.3mm, swirl/spin swing-out concentrating system can observe high culture dishes without contamination, Modular fluorescence system is easy to adjust.

$ 10530.00

Articles

The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Vacuum adsorption coating table solves the problem of film substrate wrinkling.
The vacuum adsorption coating platform uses a microporous array connected to a vacuum system beneath the tabletop to create a pressure difference, tightly adsorbing the film substrate. This ensures it remains flat during the coating process, preventing wrinkles that could lead to uneven coating.
Key points for selecting a multi-factor comprehensive test chamber with integrated temperature, humidity, vibration, and altitude systems
The multi-factor comprehensive test chamber integrates four environmental stresses: temperature, humidity, vibration, and altitude (low pressure), used to simulate the reliability of products under complex environmental conditions.
Application of Roll-to-Roll Coating Machine in UV-Curable Coatings
This article introduces the synergistic application of roll-to-roll coating machines and UV curing systems in the production of UV-curable coatings.
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Selection Guide How to Choose a Vibration Test Bench Based on Testing Standards
When selecting a vibration test system, start by carefully reviewing the test standards to clarify key parameters such as frequency range, thrust force, displacement, acceleration, and vibration type. Then, based on the standard requirements, calculate the required thrust force, match the specifications of the shaker and amplifier, and select an appropriate control system.
Corrugated Board Impact Resistance - Application of Puncture Strength Tester in Packaging Testing
The impact resistance of corrugated cardboard is crucial for transportation protection, with puncture strength being a key indicator of its ability to withstand dynamic impacts. The puncture strength tester simulates impacts using a pendulum system and measures the energy consumed to penetrate the cardboard, with results expressed in joules or kilojoules per square meter.
Preparation of silver nanowire transparent conductive films by the wire bar coating method
The preparation of silver nanowire transparent conductive films using a coating method is an efficient and scalable production process. This article systematically elaborates on the technology from aspects such as principles, materials, processes, performance characterization, and standards.
Surface Tensiometer: Interpreting the Invisible Forces on Liquid Surfaces
Surface tension is the contractile force generated by the uneven forces acting on molecules at the liquid surface, influencing phenomena such as droplet formation and capillarity. Surface tension meters measure this force using techniques like the Wilhelmy plate method, the platinum ring method, or the pendant drop method. Their core components include force sensors, sample stages, and data processing systems.
The versatile electric furnace is still being used as a hot plate, but 90% of people are unaware of these hidden functions.
In addition to basic heating, the universal electric furnace has many practical functions that are often overlooked. It features a built-in temperature control system that allows for programmed automatic heating, making it suitable for experiments requiring precise temperature control.
Don't be fooled by the specs! The 3 key metrics to focus on when purchasing a tensile testing machine.
When purchasing a tensile testing machine, don’t just look at the parameter sheet. Focus on three core indicators: first, the accuracy and range of the force measurement system; second, the accuracy of displacement and deformation measurements; and third, the performance of the control and data acquisition system.
Factors Influencing the Coating Accuracy of Laboratory Film Coaters and Calibration Methods
This article outlines the main factors affecting the coating accuracy of laboratory film applicators, including the mechanical condition of the equipment, process parameter settings, as well as material and environmental conditions. The article points out that coating accuracy directly impacts the reliability of experimental data and requires systematic methods for evaluation and control.
The working principle of laboratory wire rod coaters and methods for controlling coating thickness
The laboratory wire rod coater is a precision instrument used to prepare uniform, thickness-controllable wet film coatings on substrate surfaces. Its core components include a coating rod, a flat coating platform, clamps for securing the substrate, and a mechanical system that drives the coating rod to move at a constant speed.
Comprehensive Guide to Paint Film Thickness Measuring Instruments
This article aims to systematically outline the technical principles, applicable scenarios, and relevant standards of various paint film thickness measurement instruments, providing a reference for professional technicians.
Complete Guide to Methods for Determining the Flexibility of Paint Films
This article systematically outlines the core methods for determining the flexibility of paint films, including the mandrel bending test based on GB/T 1731, the cylindrical mandrel bending method according to GB/T 6742, and the conical mandrel bending method specified in GB/T 11185, providing a detailed explanation of the technical principles of each method.