Dual-purpose paint film thickness Gauge

The dual-purpose paint film thickness gauge utilizes magnetic induction and eddy current principles to measure the thickness of coatings on ferrous and non-ferrous substrates, respectively. It is used to detect the thickness of paint, plastic, and other coverings on metal substrates, ensuring the quality of coatings in industries such as automotive and shipbuilding.
Selection
When selecting, consider matching the substrate type with the measurement principle: use magnetic induction for ferrous substrates and eddy current for non-ferrous substrates. Check that the measurement range covers common coating thicknesses and the accuracy meets within ±3%. The portable design is suitable for on-site use, with a wear-resistant probe and temperature compensation.

Terms

Standards

Instruments

Set cross-cut adhesion, film thickness and Buchholz Crowd Hardness three test functions in one, cross-cut knife 6 blade spacing 1mm/2mm, Crowd knife load 500 +/- 5g, using the destruction Measurement principle.

$ 348.00

Using Hall and magnetic eddy current dual principle, Measurement accuracy +/- (1μm + 2% reading), equipped with wear-resistant ruby Probe, support automatic matrix switching and statistical functions, Operating temperature 0~ 50 ℃.

$ 971.00

Using magnetic Induction and eddy Current dual principle, measurement range 0-2000μm, accuracy +/- 3%, equipped with ruby probe wear and corrosion resistance, support automatic identification of iron-based and non-iron-based materials, no need to calibrate easy to operate.

$ 175.00

Iron-aluminum dual-use automatically recognizes the substrate, the split Probe is interchangeable, and the high wear-resistant cemented carbide Probe has a service life of more than 500,000 times. With zero, single point, five point calibrate and data statistics functions, it can store 1600 measurement data.

$ 314.00

With paint penetration measurement ability, accurate measurement of wall thickness without removing coatings, thickness range 2.5~ 125mm, accuracy +/- 0.03mm, support multi-echo and single-echo mode switching, suitable for detection needs of different surface conditions.

$ 2739.00

Hand type easy to operate, load 1000g, standard 6B-6H pencil, suitable for film hardness testing, test temperature 23 +/- 2 ℃ and Humidity 50 +/- 5% environment.

$ 341.00

Rotation speed is stable with stepper motor drive, Rotation speed is adjustable from 0 to 90rpm, support a variety of standard tests, avoid friction directional defects, and make the evaluation more objective.

$ 1284.00

The paint film adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel was 80mm. The integrity of the paint film was evaluated according to seven grades, and the operation was simple and reliable.

$ 267.00

Frequency 5.0MHz, support paint layer detection and emission to echo mode, Measurement range 2~ 160mm, suitable for a variety of workpiece thickness measurement.

$ 525.00

The drying process of paint film and putty film can be accurately measured by using circular track needle design, equipped with four different radius needle (R0.25/0.5/1.0/1 mm), and the track period is 24h/r.

$ 223.00

In line with ISO2808-1974 standard, the range is 0~ 150μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction control.

$ 127.00

The device adopts destructive measurement, resolution +/- 0.001mm, can carry out V-shaped incision, grid cutting and Cedar test, directly observe Coating thickness and Cedar length, support multi-layer film analysis.

$ 630.00

It can prepare a wet film thickness of 13.7 microns, with a wire-wound design providing stable coating performance. The 9.52 mm diaMeter ensures easy operation, making it suitable for various paint application scenarios.

$ 167.00

Measurement range 0-1000 microns with dual-function Probe design, wear-resistant Ruby Probe and V-groove structure, support for automatic substrate identification and zero point Adjustment.

$ 841.00

Using magnetic eddy current dual-use principle, Measurement range 0~ 1250 microns, accuracy +/- (1% -3%) H + 1.5μm, with continuous and single Measurement mode, support Data storage and statistical functions, Probe Sensitivity is high, suitable for a variety of matrix materials.

$ 428.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.