Digital Constant Temperature Stirring Machine

The digital constant temperature stirrer maintains the set temperature through heating elements and temperature sensors, while the motor drives the stirring paddle to rotate and mix the samples. It is used in laboratory processes that require constant temperature stirring, such as chemical reactions, dissolution, or homogeneous mixing, ensuring stable experimental conditions.
Selection
When selecting, consider whether the temperature range and accuracy meet the experimental requirements, ensure the stirring capacity matches the sample volume, check the adjustable speed range and stability, assess the material's corrosion resistance, verify that the operation interface is clear and user-friendly, and ensure safety protection features such as overheating power-off are included.

Terms

Standards

Instruments

Adopt digital control constant speed technology, maintain constant power operation at low speed, Max. Torque 0.3Nm, maximum processing viscosity 20000mPa · s, support reversible and timing functions.

$ 336.00

With 0~ 2400rpm stepless speed regulation function, Temperature range RT +~ 100 ℃, digital temperature control system to ensure that the solution stirring process is stable and accurate, suitable for small volume sample experimental operation.

$ 149.00

Adopt digital constant speed control technology, maintain constant power operation at low speed, Max. Torque up to 900mNm, can handle materials with viscosity up to 30000mPa · s, support forward and reverse switching and 0-9999 minutes timing function.

$ 425.00

Adopting digital control technology, constant speed closed-loop design ensures constant power operation at low speed, Max. Torque 900mNm, maximum viscosity 30000mPa · s, supports forward and reverse rotation and adjustable timing functions.

$ 386.00

Three-phase motor closed-loop control to achieve constant speed operation, low speed up to 50rpm, Max. stirring Capacity 10L, motor torque 80mN · M, suitable for high viscosity medium stirring, the shell stainless steel design is lighter.

$ 233.00

Using single chip digital control technology, with heating plate and liquid dual automatic temperature control system, Max. stirring Capacity 10L, Speed range 100~ 1500rpm, temperature control accuracy +/- 1 ℃, support 0~ 250 minutes timing function.

$ 286.00

Digital control technology implementation of deep closed loop constant speed, low speed to maintain constant Power work; Max. Torque up to 650mNm, can handle viscosity up to 20000mPa · s liquid; support reversal function, speed convenient.

$ 373.00

Driven by three-phase brushless DC motor, with large torque and strong magnetic force, Max. stirring Capacity 50L, stirring speed 60~ 1400rpm, suitable for large-capacity stirring, and equipped with digital display Rotation speed.

$ 520.00

Adopt electronic constant force speed control circuit, digital direct display shaft Rotation speed, speed range 100~ 8000rpm, maximum processing viscosity 100000mPa.s, set of dispersion function and stirring function as one, adapt to different test needs.

$ 414.00

With electric and magnetic dual stirring function, Temperature range to 100 ℃, Max. stirring Capacity 1000mL, suitable for small volume sample precise and stable stirring.

$ 180.00

Using electronic constant force speed control circuit, digital direct display Rotation speed, Power 500W, Speed range 100-2000rpm, low reliable operation noise, can calculate the relationship between stirring line speed and chemical reaction rate.

$ 403.00

With six synchronous stirring function, Max. stirring Capacity up to 6000mL, Speed range 0-2400rpm stepless adjustable, using digital temperature control system, support room temperature to 100 ℃ accurate temperature control, suitable for small volume sample experiments.

$ 344.00

Adopt microcomputer PID temperature control, temperature control accuracy +/- 0.5 ℃, ensure temperature stability. Magnetic stirring output torque, keep Rotation speed constant, over-temperature sound and light alarm to protect sample safety.

$ 1016.00

Adopt electronic constant force speed control circuit, digital direct display Rotation speed, Power 60W, Speed range 100-2000rpm, can adapt to different experimental needs, provide correct process data.

$ 204.00

Single chip digital control technology, with heating plate and liquid temperature double automatic temperature control function, temperature control accuracy +/- 1 ℃, Max.stirring Capacity 5L, support 0-250 minutes timing and 1500rpm Rotation speed adjustment.

$ 298.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.