The Spin Coater is controlled by touch screen, the acceleration range is 100~ 4000rpm/s, and the speed can be automatically corrected by A/K selection. The motor torque is large and the operation is smooth, which is suitable for the assembly line process.
The four-sided design allows for the preparation of film thicknesses of 200μm, 400μm, 600μm, and 800μm. Made of stainless steel, it offers high coating precision, a compact size, and is suitable for various substrates and coatings with different pH levels.
Two Operating Modes, point and continuous, fixed speed up to 3000rpm, track diaMeter 4mm, compact and lightweight only 3.5kg, engineering plastic shell corrosion resistance, stable operation.
Glass sensitive film can fully fit the sample sensing surface, PTFE liquid junction to ensure measurement Stability, Operating temperature range 0~ 60 ℃, suitable for semi-solid measurement.
The application width can be adjusted freely, and the drawdown blade Coater can be adapted to meet different experimental testing needs and realize flexible film operation.
Application width 500mm, wet film thickness 0.005-3mm adjustable, using servo drive and PLC control, with automatic tension and correction function, suitable for a variety of coils and Coating types.
Using HA Glass film and ceramic core liquid complex part, the film Impedance is less than 500MΩ, the reference system contains silver ion capture trap, supports wide temperature measurement at 0~ 130 ℃, and the shell is lead-free Glass, which is durable and fast Response.
Temperature range from room temperature to 200 ℃, temperature control accuracy +/- 0.3 ℃, automatic timing function to ensure accurate and reliable testing, compact structure and easy handling.
Using HF Glass film and ceramic core liquid complex structure, membrane Impedance is less than 400MΩ, equipped with NTC 30KΩ temperature sensor, support 0~ 100 ℃ wide temperature measurement, to ensure Stability and anti-interference.
Using scraping method to achieve 0.005-3mm wet film thickness, Spreader accuracy of +/- 5%, equipped with hot air circulation Oven and automatic constant tension control to ensure Spreader uniformity and Stability.
Impedance of PHY Glass film less than 500MΩ, with porous PTFE liquid complex and silver ion trap reference system, support 0~ 130 ℃ wide temperature measurement, Response is fast and stain resistance is strong.
Liquid Membrane Sensor and Skirt Cone Geometry, detection range 0.12 to 40,080 mg/L Ca2 +, operating range 4-10 pH and 0-40 ℃, to ensure measurement Stability and accuracy.
The mobile sleeve liquid fluid design, equipped with silver ion trapping trap, Glass film resistance is less than 50MΩ, and the shell is made of lead-free Glass to ensure stable measurement and durability.
Hand type easy to operate, load 1000g, standard 6B-6H pencil, suitable for film hardness testing, test temperature 23 +/- 2 ℃ and Humidity 50 +/- 5% environment.
Ultra-small portable design can be put into the pocket, equipped with protective rubber cover to prevent falling; the use of a No. 5 battery can continuously measure tens of thousands of sets of data, that is, there is no need to wait for the test; the use of special microcomputer control to eliminate external light interference, to ensure 0.1% resolution High Accuracy measurement.