Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.
Temperature range RT +~ 300 ℃, heating rate 120 ℃/h or 50 ℃/h, maximum deformation Measurement range 1mm, support thermal deformation and Vicat test, real-time display and alarm function.
Support accurate deformation of 0.01mm stride, maximum depression force 35KN, with intelligent lighting interface and adjustable LED Illuminant, suitable for steel and aluminum panel testing to ensure high contrast ratio visibility.
Temperature range RT +~ 300 ℃, heating rate 120 +/- 10 ℃/h, with sample rack lifting function, automatic stop heating at the end of the test, printable report Linear dispersion, suitable for Non-metallic material testing.
Adopt high-speed high-precision variable frequency motor control, force value range 500kg, accuracy +/- 1%, with thermal micro-printer and high-speed return function, support a variety of Measurement modes.
Using four-rail column and High Accuracy double ball screw pair structure, Force Indication Error ≤ +/- 0.5%, Test speed range 1-400mm/min, support four test modes and automatic storage function.
The Benchtop structure supports three-station testing, and the control accuracy of the constant rate heating algorithm reaches +/- 0.5 ° C. The data can be automatically recorded and exported to Excel. Transformer oil or methyl silicone oil is used as the heat conduction medium to ensure uniform heat preservation field.
With 0.001N load Graduation and +/- 0.5% accuracy, support peak hold, data storage and three units of automatic conversion, can test the spring deformation and load relationship and output level signal.
The electronic control automatic swirl/spin test is adopted, with an accuracy of 0.01mm. The special fixture effectively prevents sample deformation, and the platform is stable to ensure accurate and reliable test results.
Equipped with two kinds of shaft Rods with diaMeters of 100mm and 50mm, it can simulate the actual stress conditions, and make the sample uniform bending and deformation through the rolling shaft, which is convenient for observing the phenomenon of film crazing and peeling.
The special forming process heater has no warpage deformation at high temperature, excellent corrosion resistance of the spray panel, uniform working surface temperature, Heating power 2 × 1000KW, rapid and safe heating.
Driven by all-digital speed control system and stepper motor, the Force Indication Error ≤ +/- 0.5%, supports four test modes including fixed height force measurement value and fixed deformation force measurement value, and has automatic transmission and overload protection functions.
1000 +/- 5g dead weight and 500 +/- 5g payload combined pressure, equipped with 20 times reading Microscope to achieve 0.1mm accuracy measurement, can quantify the anti-indentation performance of coatings and support plastic deformation analysis.
Using stopwatch counting method, the length of the swing Rod is 500 +/- 1mm, and the total mass of the swing is 120 +/- 1g. The resistance to deformation is evaluated by measuring the ratio of the swing amplitude time on the film to the swing time on the Glass.
Measurement accuracy of (3 + L/200) μm, equipped with high resolution CCD and adjustable LED Illuminant to avoid thermal deformation of the workpiece.