High and low temperature impact test chamber for polymer materials

This device rapidly alternates between high and low temperature environments, subjecting polymer materials to extreme temperature fluctuations in a short period. It is used to detect issues such as cracking and deformation caused by thermal expansion and contraction, commonly applied in quality verification of electronic components and plastic products.
Selection
Select the temperature change rate based on the material thickness, and determine the inner chamber volume according to the product dimensions. Ensure the compressor power matches the temperature range, and reserve sensor interfaces for data recording. The stainless steel inner chamber should be corrosion-resistant, and the observation window must be designed to prevent condensation.

Terms

Standards

Instruments

The three-box heat storage and cold storage structure is adopted, the temperature conversion time is ≤ 10 seconds, and the temperature recovery time is ≤ 5 minutes, which can realize the rapid Impact test of high temperature 150 ℃ to low temperature -55 ℃, and meet the environmental adaptability verification of the extreme temperature of the material.

$ 18437.00

Dynamic impact testing is achieved with a two-box mobile structure. The impact conversion time is within 10 seconds, and the temperature recovery time is within 5 minutes. It is equipped with rigid polyurethane foam insulation materials to ensure low thermal conductivity and meet a number of national standards.

$ 12289.00

Using triple-channel thermal insulation structure, the damper switching time is completed within 10 seconds, and the temperature recovery time is within 5 minutes. With 96 test specification settings, the maximum Impact time is 9999 minutes, meeting the needs of high and low temperature rapid change testing.

$ 27829.00

The three-box structure is used to achieve a completely static test zone, with a temperature conversion time of ≤ 10 seconds and a temperature recovery of ≤ 5 minutes. It has an Impact range of 150 ° C in the high temperature zone and -55 ° C in the low temperature zone, meeting the needs of rapid temperature change testing.

$ 24133.00

The three-box heat storage and cold storage structure is adopted to achieve rapid temperature conversion of ≤ 10s, and the temperature recovery time is ≤ 5 minutes. It supports Impact testing at 150 ° C in high temperature zone and -40 ° C in low temperature zone, and has program memory and Linear dispersion recording functions.

$ 17307.00

Adopt three-box heat storage and cold storage structure, temperature conversion time ≤ 10 seconds, Temperature range -65 ℃~ + 150 ℃, with independent temperature control functions in high temperature zone, low temperature zone and test zone, and can perform 2-box or 3-box Impact mode.

$ 20261.00

The three-box structure is used to realize the static test sample, the heat storage and cold storage design is combined with the forced air circuit switching, the temperature conversion time is less than or equal to 10 seconds, the temperature control accuracy is +/- 0.5 ℃, and the impact conditions are independently set in the high temperature and low temperature regions.

$ 19583.00

Adopting triple-channel thermal insulation structure, the throttle switching time is completed within 10 seconds, and the temperature recovery time is completed within 5 minutes. With 96 test specification settings, the Impact time can reach 9999 minutes, and the cycle period is 9999 times, meeting the needs of High Accuracy Temperature Control.

$ 16372.00

With two-box mobile Impact structure, the temperature recovery time is less than 5 minutes, and the conversion time is only 10 seconds. Equipped with rigid polyurethane foam insulation material, it has ultra-low temperature thermal conductivity and waterproof performance, and supports programmed temperature control.

$ 14564.00

The independent control structure of the cold and hot box is adopted, with a temperature conversion time of less than 15 seconds and a temperature recovery time of less than 5 minutes. It is equipped with multiple safety interlock protection and standard lead hole design to ensure efficient and safe testing.

$ 34606.00

The three-box structure is used to achieve independent temperature control in the high temperature zone, low temperature zone and test zone, with a temperature conversion time of less than or equal to 10 seconds. It is equipped with rigid polyurethane foam insulation materials and supports 2 or 3 boxes of Impact mode to meet different standard testing requirements.

$ 12757.00

Temperature control range -70~ 150 ° C, volume 1000L, stainless steel studio and high-efficiency insulation materials, support high temperature, low temperature and constant temperature test, in line with a number of national standards.

$ 10207.00

Adopt triple-channel thermal insulation structure to realize cold and hot air circuit switching, temperature recovery time within 5 minutes, Impact time up to 9999 minutes, with 96 test specifications independently set and automatic defrosting function.

$ 22019.00

Dynamic Impact is achieved with a two-box mobile structure, with a hot and cold conversion time of 10 seconds and a temperature recovery time of 5 minutes. It is equipped with rigid polyurethane foam insulation material, with ultra-low temperature thermal conductivity and multiple safety protection devices.

$ 14564.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.

$ 8497.00

Articles