Single-head cross-cut Tester

The single-head cross-cut tester cuts a grid pattern on the coating surface using its blade and assesses coating adhesion by peeling with adhesive tape. It is used to evaluate the bonding strength of paints and inks to substrates, making it suitable for both laboratory and on-site quality inspections.
Selection
When selecting, consider the hardness of the blade material, the matching standard for blade spacing specifications, the comfort of the handle grip, and the overall structural durability. Determine the tool parameters based on the thickness of the material being tested and the testing standards, while balancing the needs for ease of operation and consistency of results.
Tooth spacing
Number of teeth
Test substrate
Measured film thickness
Number of blades
Applicable standard
Miscellaneous

Terms

Standards

Instruments

Made of 304 stainless steel, with a cross-cut length of 23-35mm, it provides four spacings of 1-3mm and 7/11 cross-cut numbers to meet different standard testing requirements.

$ 138.00

35Mm cross-cut length and 1mm pitch design, stainless steel material to ensure dimensional accuracy, equipped with tape and brush for film adhesion testing.

$ 151.00

35Mm cross-cut length with 2mm spacing design, 11 teeth to ensure test accuracy, 304 stainless steel material to ensure durability, suitable for film adhesion evaluation.

$ 151.00

Set cross-cut adhesion, film thickness and Buchholz Crowd Hardness three test functions in one, cross-cut knife 6 blade spacing 1mm/2mm, Crowd knife load 500 +/- 5g, using the destruction Measurement principle.

$ 348.00

35Mm cross-cut length with 11 teeth design, 1.5mm precise spacing to ensure test accuracy, 304 stainless steel material to ensure durability, equipped with tape and nylon brush to complete the complete test process.

$ 151.00

35Mm cross-cut length with 6 teeth design, 3mm precise spacing to ensure test accuracy, 304 stainless steel material to ensure durability, equipped with tape and brush complete set.

$ 151.00

Equipped with 1mm and 2mm cutter head spacing, the number of cutter teeth is 11, which can meet the needs of different paint film thickness testing, easy to operate and in line with international standards.

$ 186.00

Designed with 6 teeth 1mm spacing, stainless steel ensures durability, suitable for Coating thickness tests below 60 µm, in accordance with ISO/DIN 2409 standards.

$ 379.00

11 tooth cutter design, 2mm pitch, single-sided simple cutter head, can carry out cross-cut experiment, test coating adhesion, in line with a number of international standards.

$ 186.00

Hardness High Abrasion Resistance, cutting speed 20-50mm/s, suitable for film thickness 0~ 60μm, Handheld design is convenient for laboratory and field use.

$ 135.00

Automatic adjustment of the blade holder to ensure consistent pressure, ergonomic design, the cutter is easy to change without tools, wide range of teeth spacing, suitable for different Coating thickness and substrate.

$ 474.00

Vacuum hardened stainless steel material, cutting depth can be accurately adjusted, weight only 352g easy to carry, suitable for different film thickness and substrate adhesion testing.

$ 1127.00

Manual design, equipped with a 6-tooth cutting knife, with a 1mm and 2mm tooth spacing, in line with ISO2409 standards, suitable for adhesion testing in laboratories and construction sites.

$ 135.00

Equipped with three swirl/spin cutter heads, the tooth spacing is 1mm, 2mm and 3mm respectively, and it is designed according to ISO2409 standard for accurate evaluation of coating adhesion performance.

$ 183.00

Designed with 11 teeth and 1mm spacing, stainless steel ensures durability and meets ASTM D3359 standards for coating adhesion testing in the 0-50 µm film thickness range.

$ 398.00

Articles

Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Stormer Viscometer for Determining Krebs Viscosity of Paints
This article introduces the method of measuring the Krebs viscosity value of colored paints using a Stormer viscometer. Viscosity is a key indicator that affects the application and storage of coatings. The Krebs unit (KU) quantifies viscosity based on the resistance encountered by a rotor as it rotates within the paint sample.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
The laboratory pulp wet disintegrator is used for pulp disintegration treatment.
The laboratory pulp wet disintegrator is a device used to simulate the industrial pulping process. It disperses pulp fibers into individual fibers or small fiber bundles through mechanical action, while simultaneously promoting fiber swelling and fibrillation, thereby providing standardized samples for subsequent performance evaluation.