Online Turbidity Meter

An online turbidity meter measures turbidity by illuminating a liquid with a light source and detecting the intensity of scattered light from suspended particles. It is used for monitoring water quality and controlling process flows, commonly applied in industries such as water treatment and beverage production.
Selection
When selecting, consider matching the measurement range to the sample turbidity, ensuring the protection rating suits the installation environment, verifying interface compatibility with existing systems, accounting for regular calibration needs, and evaluating the sensor material's corrosion resistance.

Terms

Standards

Instruments

Adopt photometric 90 ° scattering measurement method, equipped with automatic cleaning brush and bubble measurement cell, support automatic sewage discharge and cleaning interval setting, Measurement range 0.00-500 NTU, Repeatability ≤ 2%.

$ 2783.00

Using EPA custom Illuminant and chroma compensation technology, Measurement range 0.00-4000 NTU, minimum detection limit < 0.02NTU, support automatic range conversion and multiple calibrate modes to ensure the accuracy of low turbidity measurement.

$ 3527.00

Infrared source to avoid chroma interference, built-in bubble elimination system to improve Stability, Measurement range 0-10000NTU, support multi-point correction and automatic cleaning interval settings.

$ 667.00

Simultaneous measurement of turbidity, residual chlorine and total chlorine with EPA custom Illuminant, USEPA 180.1 compliant, automatic range conversion, turbidity Measurement range from 0.00 to 4000 NTU, support for multi-unit display and GLP data management.

$ 3878.00

Micro vibration technology implementation of real-time online measurement, range 0~ 50~ 100mpa.s, accuracy +/- 0.5%, Response Time 2 seconds, suitable for a variety of fluid media.

$ 7335.00

With high and low turbidity ranges (0.00-9 and 100-1000NTU) and residual chlorine total chlorine measurement (0.00-5 mg/L), using EPA-specific Illuminant, supporting chroma compensation and Automatic calibration, storing 200 sets of data, suitable for a variety of water quality testing scenarios.

$ 2505.00

Measurement range 0-500NTU, accuracy +/- 2% FS, built-in bubble elimination system to improve Stability, support for automatic cleaning and RS485 communication.

$ 780.00

Measurement principle of 90 ° scattered light, Measurement range 0~ 400NTU, resolution 0.01, High Accuracy Optical Path System and Stable Circuit, Support Multi-turbidity Unit switch, with print interface to ensure long-term reliable work.

$ 453.00

The principle of scattered light is used for measurement turbidity, the measurement range is 0-200NTU, the resolution is 0.01NTU, the linearity is good and the operation is convenient, and it is suitable for a variety of water quality testing scenarios.

$ 262.00

Maxwell turbidity unit measurement of bacterial concentration, resolution 0.001 MCF, range 0-6MCF, with High Accuracy optical path system and low drift circuit, can store 20 records to ensure measurement accuracy and Repeatability.

$ 519.00

Measurement principle of 90 ° scattering light, Measurement range 0~ 200NTU, resolution 0.01, High Accuracy optical path system and stable circuit, support a variety of turbidity Unit switch, suitable for long-term stable operation.

$ 344.00

Simultaneous measurement of 7 water quality paraMeters, turbidity Measurement range 0-50NTU, accuracy +/- 5%, in line with USEPA 180.1 standard, with chroma compensation and Illuminant automatic compensation function, reducing interference without frequent calibrating.

$ 2363.00

High Accuracy Optical Path System to Ensure Measurement Correctness and Repeatability, Measurement range 0~ 6.000MCF, Zero drift +/- 1.5%, Support Multi-turbidity Unit Selection, Circuit Stable and Long Illuminant Life.

$ 683.00

Micro vibration technology implementation of real-time online measurement, range coverage of 0-5~ 50-5000pa.s, accuracy of +/- 0.5%, temperature 500 ℃ and Response Time only 2 seconds, suitable for high temperature and high voltage conditions.

$ 7335.00

Measurement principle of 90 ° scattering light, Measurement range 0~ 50NTU, resolution 0.01, High Accuracy optical path system and stable circuit, support a variety of turbidity Unit switch.

$ 291.00

Articles