Portable Digital Moisture Meter

Portable moisture meters detect the moisture content of substances through changes in electrical conductivity or capacitance, with a handheld design that facilitates rapid on-site measurements. They are used in industries such as coatings and inks for raw material acceptance and moisture monitoring during production processes, preventing product instability caused by moisture deviations.
Selection
When selecting, consider matching the probe type to the form of the material being tested: use puncture-type probes for powders and immersion-type probes for liquids. Verify that the measurement range covers the routine testing scope and the accuracy meets process requirements. Pay attention to the protection rating to ensure suitability for the workshop environment, and ensure calibration functions guarantee data reliability.

Terms

Standards

Instruments

Using high frequency principle, the measurement range is 0-80%, the accuracy is 0.1/0, and the Response Time is 1 second. The probe type Sensor can penetrate deep into the material. The portable design weighs about 200 grams, which is suitable for on-site rapid detection.

$ 235.00

Can store 240 sets of data, Measurement range 0-100%, provide a variety of measurement code selection, support LED status indication and LCD digital display, easy to accurately determine the moisture status.

$ 241.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using resistance principle and temperature and humidity compensation technology, the measurement range is 0-80%, the accuracy is +/- 0.5%, the Response Time is 1 second, and the portable design weight is about 203 grams, which is suitable for on-site rapid detection.

$ 144.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Low-frequency signal penetration depth of 20mm, can simultaneously measure concrete carbide moisture content and plaster moisture content, built-in environment Sensor, support a variety of professional probe expansion measurement function.

$ 1397.00

Measurement range 0~ 80%, resolution 0.1, digital and LED dual Display mode, support USB, RS-232 and Bluetooth data output.

$ 194.00

Conductivity Detector measurement principle, measurement range 0~ 84%, accuracy +/- 0.5%, Response Time 1 second, with temperature and humidity compensation technology, portable design weight only 265 grams, suitable for on-site rapid detection.

$ 160.00

Using high frequency principle, Measurement range 0-99.9%, resolution 0.1/0, Response Time 1 second, portable design can be deeply measured inside the material, backlit LCD display is clear and low power consumption.

$ 233.00

Temperature and humidity compensation technology to ensure accurate and stable measurement, Measurement range 0-84%, resolution 0.1%, Response Time less than 1 second, with MAX Maximum hold and automatic shutdown function, support a variety of data transmission interface customization.

$ 160.00

Using resistance principle and temperature and humidity compensation technology, the measurement range is 3-80%, the accuracy is +/- 0.5%, the Response Time is 1 second, the portable and lightweight is only 203 grams, suitable for on-site rapid detection.

$ 138.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Conductivity Detector temperature compensation technology, Measurement range 8~ 40%, accuracy +/- 0.5%, Response Time 1 second, with backlight display and automatic shutdown function, portable design weight only 175 grams.

$ 267.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Articles

Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.