Full-Temperature Illuminated Shaking Incubator

The full-temperature light oscillation incubator adjusts the internal temperature through a temperature control system, simulates sunlight conditions with its light module, and ensures uniform mixing of samples via an oscillation mechanism. It is used for microbial culture, plant growth studies, and material aging tests, providing controllable environmental conditions in the laboratory.
Selection
When selecting, consider whether the temperature range and accuracy meet the experimental requirements, the adjustability and uniformity of light intensity, whether the oscillation speed and amplitude are suitable for sample characteristics, whether the chamber capacity accommodates the sample quantity, the simplicity and ease of use of the operation interface, as well as the stability of the equipment and the convenience of maintenance.

Terms

Standards

Instruments

With refrigeration and heating bidirectional temperature control system, Temperature range 5~ 50 ℃, accuracy +/- 0.5 ℃, Oscillation Frequency up to 200rpm, stainless steel cavity and polyurethane insulation material, corrosion resistance and anti-interference.

$ 1027.00

With refrigeration and heating bidirectional temperature control system, Temperature range 5~ 50 ℃, accuracy +/- 0.5 ℃, Oscillation Frequency starting~ 200rpm, stainless steel cavity and polyurethane insulation material, corrosion resistance and anti-interference.

$ 2084.00

With refrigeration and heating two-way temperature control system, temperature control accuracy +/- 0.5 ℃, Oscillation Frequency starting~ 200rpm, stainless steel inner cavity corrosion resistance and Glass door for easy observation, built-in power-off protection and delay function.

$ 1124.00

With refrigeration and heating two-way temperature control system, Temperature range 5~ 50 ℃, Temperature control accuracy +/- 0.5 ℃, Oscillation Frequency starting~ 200rpm, stainless steel cavity corrosion resistance, polyurethane foam insulation anti-interference, Glass box door is convenient to observe.

$ 1124.00

Temperature range 4~ 50 ℃, temperature resolution 0.1 ℃, Oscillation Frequency 20~ 300rpm, pendulum amplitude 24mm, liner made of 304 stainless steel, providing a variety of verification services.

$ 3599.00

Equipped with 104 * 80cm large capacity liner, Oscillation Frequency 0~ 270rpm adjustable, Temperature range RT +~ 60 ℃, pendulum amplitude 50mm, suitable for liquid and solid compounds thermostatic foster, easy to operate and high stability.

$ 2276.00

Temperature range 4~ 50 ℃ and temperature resolution of 0.1 ℃, Oscillation Frequency 20~ 300rpm with 24mm swing amplitude, 304 stainless steel liner to ensure durability, support a variety of capacity configuration optional.

$ 3038.00

Temperature range RT + 5~ 60 ℃, Temperature resolution 0.1 ℃, Oscillation Frequency 20~ 300rpm, pendulum amplitude 36mm, equipped with 304 stainless steel liner and a variety of tray configurations, support Chinese and English verification services.

$ 6012.00

Set thermostatic foster and oscillation in one, Temperature Fluctuation +/- 0.5 ℃, Oscillation Frequency 40-280 rpm, AC brushless motor and antibacterial stainless steel liner, support continuous operation and timing function.

$ 1555.00

With 4~ 50 ℃ wide range temperature control and 0.1 ℃ high resolution, Oscillation Frequency 20~ 300rpm with 26mm swing amplitude, liner made of 304 stainless steel, support a variety of flask configuration and verification services.

$ 3412.00

With a two-way temperature control system, the temperature can be raised to 50 ° C in -5 ° C environment, and the temperature can be cooled to 5 ° C in 32 ° C environment; the rotary oscillation mode is adopted, and the frequency range is started to 300rpm.

$ 1163.00

Set thermostatic foster and oscillation function in one, microcomputer control temperature accuracy of +/- 0.5 ℃, Oscillation Frequency single layer 40-260 rpm, with slow start splash-proof design, stainless steel liner for easy cleaning.

$ 1531.00

Temperature range 4~ 50 ℃ accuracy 0.1 ℃, Oscillation Frequency 20~ 300rpm adjustable, swing amplitude 26mm to ensure uniform mixing, 304 stainless steel liner corrosion resistance easy to clean.

$ 4037.00

Set thermostatic foster and oscillation function in one, Microcomputer Control Temperature Frequency, Temperature Fluctuation +/- 0.5 ℃, Oscillation Frequency 40-260 rpm, AC brushless motor maintenance-free, independent temperature limit alarm system to ensure safe operation.

$ 1774.00

Temperature range 4~ 60 ℃, Oscillation Frequency 50~ 300rpm, swing amplitude 36mm, provide a variety of verification services, through the European Union CE safety certification.

$ 6915.00

Articles

Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Paper Whiteness Tester Measures CIE Whiteness
This article explains how a paper whiteness meter measures CIE whiteness. Whiteness is a crucial optical indicator for evaluating paper quality. Traditional methods rely on subjective judgment, while modern instruments provide objective data by simulating standard lighting conditions.