Handheld air Tester

The handheld air tester detects the concentration of specific gases or particulate matter by directly contacting the air through built-in sensors. It is used for rapid on-site monitoring of air quality in work environments, ensuring production safety in industries such as chemical and printing.
Selection
When selecting, confirm the types and measurement ranges of gases to be detected, check sensor lifespan and calibration cycles, consider explosion-proof ratings and protection standards, verify data recording capabilities and response time, and choose appropriate size and battery life based on the usage environment.

Terms

Standards

Instruments

The speed can reach 30000rpm, the processing capacity is 0.1-1000 ml, the 316L stainless steel dispersion head is corrosion-resistant and high temperature-resistant, and the handheld lightweight design is easy to operate with one hand. It is suitable for rapid shearing and crushing of samples in small containers.

$ 680.00

The rotating speed can reach 30000rpm, the processing capacity is 1-250ml, the handheld lightweight design is suitable for a small amount of samples in a small container, and the corrosion-resistant stainless steel dispersion head is used for easy disassembly and cleaning. Double insulation protection ensures safety.

$ 709.00

Measurement range 58~ 92% Brix, minimum reading 0.002, scale reading mode, compact shape only 155mm long, Net weight 160g for handheld operation, suitable for a variety of liquid concentration detection.

$ 122.00

Rotation speed 5000~ 30000rpm, Processing capacity 0.2~ 80ml, handheld operation is light and convenient, suitable for outdoor or laboratory mobile use, providing High Accuracy stainless steel cutter head.

$ 880.00

The volume is only the size of the palm, the weight is less than 1 kg, and it supports 12V DC power input. Temperature control accuracy up to +/- 0.3 ° C, equipped with 5-stage programmable temperature control, built-in high-speed fan for fast cooling, easy module replacement and cleaning.

$ 304.00

Handheld, lightweight and portable, large-capacity battery supports outdoor mobile operation, Rotation speed 5000-30000rpm, Processing capacity 0.2-150 ml, stainless steel material corrosion resistance, double insulation protection is safe and reliable.

$ 517.00

Suitable for medium-hardness rubber, thermoplastic elastomers, and plastics, with a measurement range greater than 90 HB and less than 20 HD, compliant with ASTM D2240 standard, and supports both handheld and benchtop usage modes.

$ 178.00

Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.

$ 1009.00

Designed with a large outer diaMeter of 22mm, Processing capacity range of 10-100ml, suitable for handheld devices, length 101mm for easy operation, internal thread aperture 8mm to ensure stable connection.

$ 199.00

Vertical double air duct vertical hot air circulation to ensure temperature uniformity, speed control fan can adjust the air volume to avoid blowing powder items, Temperature range RT + 10-300 ℃, studio volume 225L, equipped with independent temperature limit alarm system to ensure experimental safety.

$ 1474.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, speed control fan can adjust the air volume according to experimental needs, Inner Chamber dimensions 350 × 350 × 350mm, volume 42L, with independent temperature limit alarm system and paraMeter memory function.

$ 925.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, Inner Chamber dimensions 310 × 310 × 310mm, variable speed fan can adjust the air volume, large screen LCD display multiple sets of data, with paraMeter memory and over-temperature alarm function.

$ 832.00

Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.

$ 683.00

Vertical double air duct vertical hot air circulation to ensure temperature uniformity, temperature control accuracy of +/- 1.0 ℃, turbine centrifugal fan blade with the drum design, fan speed adjustable, studio mirror stainless steel easy to clean.

$ 1248.00

Adopt vertical double air duct vertical hot air circulation, temperature control accuracy +/- 1.0 ℃, Temperature resolution 0.1 ℃, with timing and over-temperature alarm function, turbine centrifugal fan blade with bottom drum and bottom heating to ensure Temperature uniformity.

$ 1719.00

Articles

Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Sheffield Smoothness Tester for Analyzing Paper Printing Surface
This article introduces how the Sheffield smoothness tester analyzes the printing surface of paper. The instrument quantifies paper smoothness by measuring the air leakage time, with a longer time indicating a smoother surface.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
What is the difference between the Bendtsen method and the Gurley method for measuring paper air permeability using an air permeability tester?
The air permeability of paper is a key indicator for evaluating its structural compactness and suitability, especially crucial in fields such as packaging, filtration, and specialty papers. The Bendtsen and Gurley methods are two classic and widely used techniques for determining paper permeability.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.