Halogen Moisture Content Analyzer

The halogen moisture analyzer uses a halogen lamp to heat the sample, causing moisture to evaporate. It then calculates the moisture content in real-time by measuring the weight loss. This instrument is used for moisture detection in materials such as coatings and plastics to ensure production quality.
Selection
When selecting a halogen moisture analyzers, consider sample characteristics, temperature range, weighing accuracy, and heating uniformity. Match the sample form and moisture content to ensure the instrument meets daily testing requirements.

Terms

Standards

Instruments

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using halogen lamp heating technology, Capacity 110g, moisture readability 0.02%, with RS232C Communication interface, Heating Temperature range RT +~ 200 ℃, suitable for rapid drying analysis of various samples.

$ 420.00

It adopts annular halogen lamp heating and multi-layer stainless steel heating Chamber, heating up fast and uniform, moisture measurement accuracy of 0.1%, equipped with German imported Sensor to ensure stable weighing, support data storage and printing functions.

$ 1124.00

Using halogen lamp heating technology, Capacity 110g, temperature adjustment accuracy +/- 1 ℃, rapid drying of samples and real-time display of moisture percentage, suitable for a variety of sample detection.

$ 483.00

Using annular halogen lamp heating, heating fast and uniform, Heating Temperature range RT + 40~ 199 ℃, moisture accuracy of 0.1%, with imported Sensor to ensure stable weighing, support data storage and printing.

$ 814.00

The annular halogen lamp is uniformly heated, Capacity 50g, moisture measurement range 0.00-100%, heating temperature can reach 160 ℃, the general sample can be measured in just a few minutes, and the detection efficiency is high.

$ 388.00

Using halogen lamp heating technology, Capacity 110g, readability 0.001g, heating temperature up to 200 ° C, fast drying and real-time display of moisture percentage, suitable for a variety of sample analysis.

$ 566.00

Using annular halogen lamp heating, Temperature range RT +~ 180 ℃, the fastest few minutes to complete the measurement; Equipped with Draft Shield and imported Sensor, the heating performance is uniform and stable, supporting the simultaneous conversion of water content and solid content.

$ 441.00

Fast heating with halogen lamp and High Accuracy Sensor, the cast aluminum shell is durable, the temperature and time are adjustable, and multiple drying processes can be memorized to achieve percentage display of Moisture content.

$ 469.00

Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.

$ 330.00

Using an annular halogen lamp to heat uniformly, the sample is rapidly dried in just a few minutes, the moisture measurement range is 0.00 to 100%, and 9 paraMeters including water loss rate and temperature can be displayed.

$ 344.00

Ring halogen lamp heating, 0.02% moisture readability, RT +~ 180 ℃ Temperature range, automatic measurement, Draft Shield design, pure stainless steel heating Chamber cover, 16 sets of Data storage.

$ 503.00

The annular halogen lamp is used to heat the sample evenly and quickly, and the surface is not easily damaged. Capacity 100g, moisture measurement range 0.00~ 100%, and the general sample can be measured in a few minutes.

$ 388.00

Using halogen lamp rapid heating technology, Capacity 150g, moisture readability 0.01%, real-time display of dynamic Linear dispersion and experimental data, support audit trail and user rights management.

$ 669.00

Articles

Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.