Spectrophotometric Color Formulation System

The spectrophotometric colorimeter analyzes color parameters by measuring the spectral data of light reflected or transmitted by an object. It is used in industries such as coatings and plastics to control color consistency in production, assist in color matching, and conduct quality inspections.
Selection
When selecting a spectrophotometric color measurement instrument, it is essential to consider measurement accuracy, repeatability, instrument type (such as 0°/45° or integrating sphere), compliance with industry standards, evaluation of software functionality, and sample adaptability to ensure it meets practical application requirements.

Terms

Instruments

The fan-shaped matte design contains 1188 standard colors, conforms to the national standard GB/T15608-2006, and provides a complete water-based paints formula system and colorants formula table. The colors are divided into seven series.

$ 105.00

Using Spectrophotometric method, spectra-trophotometry to detect nickel concentration, detection limit of 0.1mg/L, equipped with imported cold light source life of 100,000 hours, support a variety of Measurement mode and wireless data transmission function.

$ 816.00

Based on o-phenanthroline Spectrophotometric method, spec-trophotometry, the detection limit is up to 0.01mg/L, the imported cold light source does not need to be preheated, and supports continuous Measurement mode. Colorimetric integrated tube operation is safe and fast.

$ 816.00

Adopt 165 ℃ thermostatic digestion and spectrophotometric detection technology, detection range 0~ 20000mg/L, support digestion Colorimetric integrated tube design, built-in rechargeable battery, can store 4000 sets of data and support a variety of transmission interfaces.

$ 2526.00

Matte design system Color, including 290 commonly used Colors, 5 color samples per page 3.1x5.0cm, convenient for industry color comparison and application reference.

$ 93.00

Equipped with five Illuminant system, supports D65, TL84 and other Standard light sources, the interior is coated with Moncel gray N5.5, the width is 60cm, and the multi-point Illuminant observation system enhances the accuracy of color evaluation.

$ 4022.00

Adopt 45/0 illumination light receiving system, 8mm measurement aperture, support single and average Measurement mode, Repeatability Standard Deviation ≤ E * within 0.1, can carry out color difference contrast analysis and color quality control.

$ 307.00

Optical inspection system with infinity, semi-retouching color difference objective and phase contrast condenser provides 40X-1000X magnification for viewing thicker samples and enhancing the three-dimensional profile of cell structure.

$ 3975.00

Adopting D/8 geometrical optics structure, supports Φ 8/4mm dual aperture switching, simultaneous measurement of SCI and SCE, Light spectrum reflectance Repeatability Standard Deviation within 0.08% to ensure accurate and reliable Color data.

$ 4882.00

Optical inspection system with dual beam of light feedback compensates for Illuminant fluctuation in real time, Light spectrum reflectance Repeatability Standard Deviation is less than 0.1%, and the inter-device difference Delta E * ab is as high as 0.08, which can accurately measure fluorescent materials without UV correction.

$ 27183.00

The Fan Color Chart contains 1825 semi-matte Colors, with a color sample size of 2.5x5cm. It provides multi-language auxiliary name translation, and the upgraded model adds 200 new colors, which is convenient for industry color standardization applications.

$ 296.00

Using electric pressure system, the printing pressure is adjustable from 0 to 2mm, the speed range is 0 to 80 Meters, low accuracy overprinting is supported, and the computer program control operation is stable.

$ 5915.00

The printing pressure can be adjusted accurately according to the thickness of the material, and the printing speed can be adjusted. It provides 4 primary color areas and 4 light color areas to ensure that the pattern is clear and tidy.

$ 4527.00

The 195 color difference objective improves the image contrast ratio, supports 40X to 1600X magnification range, and is equipped with a liftable Abbe condenser and a double-decked mechanical stage to ensure comfortable and accurate observation.

$ 525.00

Using tungsten lamp and silicon photoDetector combination, equipped with narrow band Interference filter to ensure Measurement accuracy +/- 2mm; Cuvette locking system to maintain 10mm optical path conformity, support automatic shutdown energy saving.

$ 811.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.