Small Automatic Glue Dispensing Machine

The small automatic glue applicator utilizes a motor to drive the rotation of the glue roller, evenly transferring adhesive onto the surface of the substrate. It is designed for laboratory-scale small-batch sample coating and can simulate various coating methods such as knife coating and wire rod coating. It is suitable for the preparation of adhesive coatings on materials such as paper and films.
Selection
When selecting, consider matching the substrate width to the coating width, aligning the adhesive viscosity with the roller gap, and determining the precision grade based on the required coating thickness. Check whether the motor speed adjustment range covers the process requirements, and note that the ease of cleaning and maintenance affects usage efficiency.

Terms

Standards

Instruments

Using 470nm wavelength and double-sided LED Illuminant irradiation, equipped with amber filter and 105 * 163mm glue cutting area, accurate fluorescence sample separation operation can be achieved.

$ 201.00

Film Film thickness 22.9μm, Spreader width 30cm, wear-resistant stainless steel material, molding process, suitable for low viscosity glue and thermal glue experimental Spreader.

$ 186.00

Using double-sided LED Illuminant and 400nm wavelength, equipped with amber filter, the glue cutting area is up to 105 * 163mm, which is convenient for accurate separation of fluorescently labeled nucleic acid protein samples.

$ 212.00

Using 365nm wavelength double-sided LED Illuminant, equipped with amber filter, the glue cutting area is up to 105 * 163mm, which can clearly observe the fluorescence and accurately separate the target area.

$ 223.00

Automatic calibration without preheating zero adjustment, 1.5 seconds fast measurement, accuracy of 0.1, equipped with 4mm small diaMeter measurement head, support connecting mobile app and computer software to achieve Data storage and report export.

$ 202.00

Adopt 4mm small diaMeter design, accuracy of 0.1, 1.5 seconds fast measurement, support Automatic calibration and APP Data storage, equipped with ceramic whiteboard luminance value greater than 90.

$ 170.00

Adopt 4mm small diaMeter design, suitable for surface or small area measurement; Repeatability Delta E * ab < 0.05 to ensure Measurement accuracy; Horizontal structure is small in size, comfortable and stable to hold.

$ 1203.00

Using a small amount of sample adapter and SC4 rotor, the sample dosage is only 2-16ml, the viscosity range is 100~ 6.6mPa · s, the temperature accuracy is +/- 0.1 ℃, and it supports continuously variable speed and automatic lifting, shortens the thermostatic time and improves the measurement accuracy.

$ 5023.00

Using slot-die coating method, application width ≤ 500mm, thickness range 10-250μm; equipped with automatic deviation correction and constant tension system, Oven temperature RT +~ 160 ℃, support segmented thermostatic, ensure Spreader accuracy +/- 3 microns.

$ 61393.00

Spreader thickness range of 10-250μm, Dry-Film accuracy of +/- 3 microns, equipped with automatic constant tension control and four Oven section thermostatic, ensure uniform and stable Spreader, Oven with waste heat recovery system energy saving about 30%.

$ 48484.00

The formed pRoduction process ensures that the film is uniform, the film thickness is 22.9μm, the application width is 300mm, which is suitable for low viscosity glue experiment, and the material is wear-resistant stainless steel to prolong the service life.

$ 167.00

The equipment adopts High Accuracy modular Spreader station, all-electric control without air source, minimum glue thickness 0.01mm, Spreader speed 2-4.5 m/min adjustable, with electronic control precision tension to adapt to a variety of materials such as paper, plastic and metal film.

$ 5721.00

The ultra-small design is easy to carry, the automatic zero stabilization function does not need to be calibrated, the moisture-proof process adapts to the harsh environment, the Measurement range is 0~ 199.9, the accuracy is 0.1, and the use of a No. 5 battery can work continuously for more than 50 hours.

$ 767.00

Using automatic mechanical pressurization and heating technology, the inlay process is completed automatically, the Heating power is 650W, and the mold sleeve specification is 25mm, which is suitable for edge protection of small irregular samples.

$ 3612.00

Adopting dip coating with double roll extrusion structure, Spreader thickness 0.3-10 mm adjustable, mechanical speed 1.2m/min can be slowly adjusted, built-in glue circulation system to ensure Spreader uniformity.

$ 29120.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
The Stripe Issue Caused by Tension Fluctuations in Roll-to-Roll Laboratory Coaters and Its Solutions
This paper analyzes the causes of and countermeasures for coating streaks resulting from tension fluctuations in roll-to-roll laboratory coaters.
Analysis of Common Defects in Laboratory Coating Machine Blade Coating and Adjustment Methods for Process Parameters
This article introduces common defects in the blade coating process of laboratory coaters, such as streaks, orange peel, bubbles, uneven thickness, and missed coating. It analyzes the causes of these issues, which are primarily related to material properties, operating parameters, and environmental factors.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Using a spray coater to achieve the preparation of functionally graded films.
This paper introduces a method for preparing functionally gradient films using a spray coating machine.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Operation Tips for Laboratory-Scale Hot Melt Adhesive Coating Machines
This article introduces the key operational points of a laboratory-scale hot melt adhesive coater. The equipment is primarily used in laboratories to apply hot melt adhesives uniformly onto substrates, supporting the research, development, and testing of adhesives.
Application of Continuous Coating Machine for Lithium Battery Electrode Preparation in Electrode R&D
The laboratory continuous coater is a key piece of equipment in lithium battery electrode research and development, used to simulate mass production coating processes. By precisely controlling parameters such as coating speed, thickness, and tension, it helps researchers optimize slurry formulations and coating procedures.
How to Coat High-Viscosity Slurry – Parameter Setting Tips for Blade Coaters
This article primarily discusses the parameter setting techniques for high-viscosity slurries on blade coaters. High-viscosity slurries exhibit characteristics such as shear thinning, so it is essential to leverage shear effects during coating to facilitate slurry spreading. After coating, the viscosity should recover quickly to prevent sagging.
Common Troubleshooting for Wire Bar Coater: Solving Issues of Streaking and Uneven Thickness
This article mainly introduces solutions to two common faults in the operation of the wire rod coater—coating streaks and uneven coating thickness.
Roll-to-roll coater enables continuous preparation of flexible electronic materials.
Roll-to-roll coating is a continuous production process that involves uniformly applying functional slurry onto a flexible substrate, followed by drying and curing to form a functional film.