Automatic Chloride Ion Content Analyzer

The automatic chloride ion content analyzer employs the potentiometric titration method, using a silver electrode to detect the potential jump point generated by the reaction between chloride ions and silver ions, and automatically calculates the chloride ion concentration. It is used to detect chloride ion content in water quality, building materials, and chemical products, ensuring material performance and safety.
Selection
When selecting, consider matching the sample type to the detection range, ensure potentiometric titration meets precision requirements, use automatic sampling to improve efficiency, incorporate anti-interference design to adapt to complex samples, opt for a simple and user-friendly operation interface, and ensure stable maintenance costs and consumable supply.

Terms

Standards

Instruments

Adopt automatic potential Titrimetric method, built-in standard method to directly read the results, support silver nitrate (AgNO3) calibration and blank experiment, data management can store 200 sets of results, titration analysis Repeatability of 0.20%.

$ 3667.00

With manual and automatic temperature compensation function, Measurement range 0-6 PCL, resolution up to 0.01 PCL, easy operation and intuitive and accurate digital display, suitable for a variety of water quality monitoring scenarios.

$ 382.00

Designed for chloride ion composite ElectRode, provides stable calibrating performance, Encasement size 250ml, to ensure long-term use Reliability and measurement conformity.

$ 110.00

Specially designed for lead chloride ion composite ElectRode, providing stable reference potential to ensure the accuracy of ion measurement, Encasement capacity 250ml, suitable for routine laboratory testing.

$ 99.00

With 5 point Adjustment, Measurement accuracy 0.5% F.S., Support automatic temperature compensation and end point locking, can store 500 sets of data and comply with GLP specifications, provide a variety of concentration unit selection.

$ 696.00

Refractive index measurement technology, only 1.5 seconds to display the results, automatic temperature compensation range 10-40 ℃, sample size only 100 μL, IP65 Protection Rating for a variety of environments.

$ 567.00

With manual and automatic temperature compensation function, concentration Measurement range 1 × 10 ^ ²~ 5 × 10 ^ mol/L, the fastest reaction time is less than 4 minutes, support pFe value and iron Ion concentration display.

$ 382.00

1000Pppm standard concentration to ensure the accuracy of calibrating, PTFE material solution bottle effectively prevent contamination, 480mL capacity to meet the needs of conventional use, universal design for a variety of ion measurement scenarios.

$ 135.00

Measurement range 0.23 nm g/L to 23 g/L, temperature compensation 5~ 50 ℃, suitable for high purity water and industrial drainage sodium ion concentration determination, repeatability error does not exceed 0.03pNa.

$ 262.00

With manual and automatic temperature compensation function, Measurement range 0-6 pF, resolution up to 0.01 pF, support fluorine Ion concentration value display, easy operation and digital display intuitive and accurate.

$ 262.00

Measurement accuracy of 0.5% and automatic temperature compensation, 2-5 point calibrating and concentration Unit switching, 500 data storage and GLP compliant, backlit display and USB Communication interface.

$ 696.00

Measurement accuracy of 0.5% F.S. with 5 point button calibrating and automatic end point locking, 500 data storage and automatic temperature compensation, suitable for a variety of Ion concentration unit selection.

$ 696.00

4 groups of samples can be tested at the same time, using PID precise temperature control technology, Temperature range from room temperature to 1000 ℃, with automatic calculation of carbon black content and ash content function, open lid structure heat dissipation effect is better.

$ 6205.00

Adjustment with 5 point buttons, 8 Ion concentration calibrated point selection, Measurement accuracy of +/- 1% FS, automatic temperature compensation to ensure full scale accurate measurement, 500 data storage and GLP compliance.

$ 696.00

With 0.5% F. S Measurement accuracy and automatic temperature compensation function, supports 2-5 point calibrating and 500 sets of Data storage, equipped with backlit display and USB interface, suitable for a variety of Ion concentration unit measurement.

$ 696.00

Articles

Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Key operational points for determining chloride ion content in water using automatic potentiometric titrators
This article introduces a method for measuring chloride ions in water using an automatic potentiometric titrator. It is based on silver nitrate titration, where the endpoint is automatically determined by a sharp change in electrode potential, offering greater accuracy and higher automation compared to traditional methods.