Portable Concentration Meter

Portable concentration meters detect liquid concentration through light refraction or changes in electrical conductivity. Their handheld design is suitable for on-site rapid measurements, used in quality control for applications such as beverage sugar content and industrial acid-base solutions.
Selection
Choose refractive or conductive based on the type of substance to be measured; consider the measurement range to cover daily sample intervals; verify the temperature compensation function; ensure the protection rating is suitable for the usage environment; select a model with convenient calibration.

Terms

Standards

Instruments

With 0~ 35% soy milk concentration Measurement range, accuracy +/- 0.3, support automatic temperature compensation and user-defined zero point, anti-light interference design, adapt to a variety of environments.

$ 304.00

Using 6.44ppt high concentration calibrated liquid, Encasement alone to ensure freshness, light block Encasement anti-ultraviolet oxidation, valid period of up to 5 years, suitable for field and portable use.

$ 167.00

Measurement accuracy of 0.5% and automatic temperature compensation, support 2-5 point calibrating and 500 data storage, equipped with backlit display and USB interface, suitable for Ion concentration detection in various environments.

$ 696.00

Detection of oxygen concentration 0~ 25% range, resolution of 0.1%, Response Time ≤ 15 seconds, Portable design, suitable for a variety of environment monitoring needs.

$ 162.00

With 1% F. S Measurement accuracy and automatic temperature compensation function, it supports 500 sets of Data storage and a variety of Ion concentration unit selection, equipped with large screen backlight display and automatic ElectRode diagnostic system.

$ 696.00

Measurement accuracy of 0.5% and automatic temperature compensation, 2-5 point calibrating and concentration Unit switching, 500 data storage and GLP compliant, backlit display and USB Communication interface.

$ 696.00

Measurement accuracy of 0.002pH, automatic identification of ElectRode type and 500 sets of Data storage, suitable for accurate analysis in a variety of environments.

$ 528.00

With 5 point button calibrating and automatic temperature compensation function, Measurement accuracy of 0.5% F.S., built-in 500 data storage capacity, support for a variety of Ion concentration Unit switches, equipped with backlit LCD display.

$ 696.00

Adopt independent ozone concentration controller for long-term stable non-drift, equipped with high voltage silent discharge tube ozone generator, concentration range 10~ 1000pphm, Temperature Fluctuation +/- 0.5 ℃, support static tensile specimen and sample rack speed 1~ 2rpm.

$ 11079.00

Equipped with a large screen backlight display, supports 2 to 5 point calibrating and automatic temperature compensation, Measurement accuracy of +/- 1% F.S., can store 500 sets of data and has automatic ElectRode diagnostic function to ensure stable and reliable measurement.

$ 696.00

With 0.5% F. S Measurement accuracy and automatic temperature compensation function, supports 2-5 point calibrating and 500 sets of Data storage, equipped with backlit display and USB interface, suitable for a variety of Ion concentration unit measurement.

$ 696.00

Using refraction principle design, LCD large-screen liquid crystal digital display, quick display results within 3 seconds, automatic temperature compensation function, more than 10,000 times of use, with automatic shutdown and power alarm function.

$ 251.00

The diazotization method is used to react with nitrite to generate pink color. Measurement range is 0~ 600μg/L, and 100 tests are provided. It is suitable for a variety of Photometers to ensure accurate and reliable concentration determination.

$ 186.00

Volume 12 liters, the concentration of 5% -35%, equipped with manual speed regulation and digital Rotation speed display function, stainless steel material and new sealing technology to prevent leakage.

$ 3946.00

Measurement range 0-999 ppb with accuracy +/- 20 ppb +/- 5% for rapid iron concentration detection.

$ 215.00

Articles

How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Valley Beater in Pulp Laboratory Beating
The Valley beater is a device used in laboratories to simulate industrial beating processes. It modifies the morphology of pulp fibers through mechanical action, thereby influencing paper properties. During operation, parameters such as beating pressure, pulp consistency, and beating time must be controlled, with the beating degree serving as a quantitative measure of the effect.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.