High-speed 3D disperser for coatings.

The three-dimensional high-speed disperser for coatings creates a three-dimensional circulation flow within the container through multi-layered serrated impellers, utilizing high-speed shear forces to rapidly mix and disperse powdered materials with liquids. It is used for pigment de-agglomeration and homogenization in paint production, capable of handling high-viscosity materials and reducing mixing time.
Selection
When selecting, consider the viscosity of the material to match the motor power, determine the tank volume based on batch capacity, choose the impeller type according to dispersion fineness requirements, use stainless steel material to accommodate corrosive raw materials, employ explosion-proof motors for flammable solvent environments, and utilize variable frequency speed control to adapt to different process stages.

Terms

Standards

Instruments

Measurement accuracy XY +/- 0.5μm, Z +/- 1μm. Support multi-depth fusion and 2D to 3D imagery, can automatically collect images in the range of 10μm~ 100μm, and the repeability Measurement accuracy error is controlled within 5%.

$ 48161.00

Speed range 0~ 20000rpm wide adjustable, equipped with high-speed series motor and stable silicon control system, integrated photoelectric speed measurement to ensure accurate reading, compact structure and convenient operation.

$ 351.00

Adopt thyristor high-speed adjustment system, photoelectric speed measurement electronic circuit to ensure reliable Rotation speed, homogenization knife Speed range of 22000rpm, Processing capacity 1000ml, easy to operate and intuitive reading.

$ 361.00

Adopt electronic constant force speed control circuit, digital direct display shaft Rotation speed, speed range 100~ 8000rpm, maximum processing viscosity 100000mPa.s, dispersion head generates swirl/spin tangential high line speed under high speed drive, through hydraulic shearing and high frequency mechanical effects to achieve efficient mixing, dispersion and homogenization.

$ 333.00

The equipment uses an electronic constant force speed line, digital direct display Rotation speed, speed range of 100 to 8000rpm, maximum processing viscosity of 100000mPa.s, to adapt to different test needs, through high-speed shearing and high-frequency mechanical effects to achieve efficient mixing and dispersion.

$ 436.00

The equipment integrates stirring, dispersing, grinding functions, motor Power 750W, speed range 60~ 8000rpm, can handle materials with a viscosity of 100000mPa.s, through high-speed swirl/spin to generate strong shear force to achieve efficient Mixing & dispersing.

$ 675.00

With red and blue laser dual mode fast switching, accuracy up to 0.03mm, scanning rate of 480,000 times/second, support automatic positioning and dynamic measurement, external environment influence is small, can work in direct sunlight.

$ 42239.00

The swirl/spin design is firm and abrasion-free, with a three-dimensional roll tilt angle of 10 °, a speed range of 10-70rpm, and a maximum load of 5kg. It can be used in low temperature and Thermal Chambers.

$ 472.00

Set dispersion and Stir functions in one, the two processes of dispersion and homogenization are completed by one machine, with high efficiency, good mixing effect and easy cleaning. Speed range 100~ 8000rpm, maximum processing viscosity 100000mPa.s, electric lifting mode is simple and convenient to operate.

$ 493.00

With a wide speed range of 0~ 10000rpm and 280mm lift Travel, using frequency conversion electromechanical operation quiet noise, support high-speed dispersion, stirring and grinding functions, suitable for 0~ 2L Processing capacity.

$ 772.00

The equipment uses a spring lift system, lift Travel 200mm, speed range of 60~ 8000rpm, can adapt to different experimental needs, through the digital PID technology implementation High Accuracy control, and provide dispersed impeller and sand grinding disc.

$ 801.00

Measurement of thick soft coatings such as polyurea and asphalt, thickness range 50 to 7600 μm, storage of 100,000 readings, ASTM D6132 compliant, non-destructive ultrasonic technology, durable and easy to operate.

$ 3987.00

Adopting crane bearing swirl/spin design, no abrasion and suitable for long-term operation; speed range 10-80rpm, maximum load 5kg; molded shell is acid and alkali resistant and easy to clean, can be used in the refrigerator.

$ 430.00

The axial flow fan is used to supply air and support stepless speed regulation of 0~ 3m/s, and the anemoMeter has a range of 0~ 10m/s, which is suitable for the determination of the initial drying anti-cracking performance of laminated architectural coatings.

$ 490.00

The equipment adopts electronic constant force speed regulation, Speed range 100~ 8000rpm, maximum processing viscosity of 15000mPa.s, high-speed shearing and high-frequency mechanical effects to achieve efficient mixing and dispersion.

$ 414.00

Articles

Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.
Wear testing machine evaluates the wear resistance performance of wood and floor coatings.
This article introduces how to use a wear testing machine to evaluate the wear resistance of wood and floor coatings.