Thermal Alarm

The temperature alarm monitors the ambient temperature through sensors and triggers audible and visual alerts when the values exceed the preset range. It is used for overheating protection in equipment such as ovens and reaction vessels to prevent material deterioration or equipment damage.
Selection
When selecting, match the range with the process temperature, consider the probe's corrosion resistance, confirm that the response speed meets safety requirements, check certification marks to ensure compliance, and evaluate the installation method for compatibility with the site.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Standards

Instruments

With 260 * 200 thermal imagery resolution and 70mK thermal Sensitivity, it can quickly locate the abnormal temperature rise point of the circuit board, support -10~ 120 ℃ temperature measurement range, equipped with adjustable lens and multi-directional adjustment bracket, easy to accurately observe the thermal distribution of the circuit board.

$ 1022.00

Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.

$ 19809.00

Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.

$ 23682.00

Temperature range RT +~ 300 ℃, heating rate 120 ℃/h or 50 ℃/h, maximum deformation Measurement range 1mm, support thermal deformation and Vicat test, real-time display and alarm function.

$ 2010.00

Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.

$ 2300.00

The transient planar heat source method is used, the test time is not more than 160 seconds, the Sensitivity is 0.00001, and the thermal conductivity of 0.0001 to 50W/(m * K) can be measured. It supports a variety of morphological samples and meets international standards.

$ 12983.00

Using oil Bath heating medium, Temperature range from room temperature to 200 ℃, temperature control accuracy +/- 0.5 ℃, equipped with sample clamping grid to ensure temperature stability, suitable for various film thermal cissing rate tests.

$ 1510.00

The two-box mobile structure is adopted, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. It is equipped with HFC environmentally friendly refrigerant and binary ultra-low temperature freezing system, which has high cooling speed and efficiency. It supports paperless recording and real-time Linear dispersion display function.

$ 16840.00

Temperature resolution of 0.1 ℃ and heating rate of 0.1~ 20 ℃/min can be adjusted continuously. It supports hot stage method and visual measurement, and is suitable for the study of thermal characteristics of trace samples.

$ 5971.00

Temperature resolution is up to 0.1 ℃, heating rate is adjustable from 0.1 ℃ to 20 ℃/min, hot stage method and visual measurement are supported, which is suitable for the study of thermal characteristics of trace samples.

$ 4600.00

The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.

$ 21858.00

Temperature range -40 ℃ to + 150 ℃, the temperature conversion time is only 10 seconds, using PID full digital automatic Control system, can quickly detect the material in the extremely high temperature and low temperature continuous environment resistance and thermal expansion and contraction changes.

$ 17303.00

Using three-box equipment structure, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy reaches +/- 0.5 ℃, and the air circuit switching method realizes fast Thermal Shock, which is suitable for material physical and chemical change testing.

$ 38156.00

Dynamic Impact is achieved with a two-box mobile structure, with a hot and cold conversion time of 10 seconds and a temperature recovery time of 5 minutes. It is equipped with rigid polyurethane foam insulation material, with ultra-low temperature thermal conductivity and multiple safety protection devices.

$ 14564.00

Two-box mobile structure, air pressure driven test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL, IEC and other specifications, with paperless recording and real-time Linear dispersion display function.

$ 17985.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.