Cart Oven

The trolley oven generates hot air through electric heating, which circulates inside the chamber to heat and dry materials. The trolley structure facilitates the loading and unloading of heavy or large quantities of samples, making it suitable for curing and drying processes in industries such as coatings and plastics.
Selection
When selecting, consider matching the chamber size to the sample volume, and ensure the maximum temperature covers the process requirements. Pay attention to heating power and temperature uniformity, and ensure the trolley's load capacity and track design are compatible with the material weight. Choose between hot air circulation or vacuum types based on the material characteristics.

Terms

Standards

Instruments

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

Using dip coating process with double roll extrusion residual material, Spreader thickness adjustable, mechanical speed 0.1-1 m/min, Oven temperature 50-150 ℃ +/- 3 ℃, suitable for a variety of Coating Spreader.

$ 21051.00

Equipped with 8 Meters Oven, roller heating temperature up to 200 ℃, effective application width 500mm, Spreader thickness range 0.005-3mm, support automatic unwinding to winding process, suitable for hot-melt adhesive film.

$ 29120.00

Support 0-3000um Coating thickness adjustment, travel speed 0-5m/min, Oven temperature 40-150 ℃; Modular head can switch extrusion, Drawdown blade and other Spreader functions, integrated tension closed-loop control and infrared drying options.

$ 9433.00

Using roll-to-roll continuous solution pool mode, the width of the substrate is 200mm, and it is dried by 130 ° C hot air Oven; the solution pool can be lifted and heated, and PLC control ensures stable operation, which is suitable for a variety of substrate processing.

$ 48484.00

Microcomputer P.I.D temperature controller, temperature control accuracy +/- 1.0 ℃, volume 136L, with hot air circulation system to improve Temperature Uniformity, support independent temperature limit alarm and optional programming function.

$ 749.00

Adopt double roll extrusion method to achieve 0.3-10 mm Spreader Film thickness, accuracy of +/- 0.05mm; Equipped with hot air circulation Oven, Temperature range room temperature to 200 ℃ +/- 3 ℃; Tension controller automatically controls the unwinding process to ensure the uniformity of Spreader.

$ 10562.00

Volume 80L, Input Power 850W, Microcomputer P.I.D temperature controller and hot air circulation system to ensure Temperature Uniformity +/- 3%, with over-temperature protection and timing function.

$ 417.00

Large LCD screen, Menu Operating interface, Temperature Fluctuation +/- 1 ℃, Mirror stainless steel liner for easy cleaning, Thickened box design low surface temperature, Thermal Power reduced by more than 25%.

$ 803.00

Spreader thickness range of 10-250μm, Dry-Film accuracy of +/- 3 microns, equipped with automatic constant tension control and four Oven section thermostatic, ensure uniform and stable Spreader, Oven with waste heat recovery system energy saving about 30%.

$ 48484.00

Ceramic fiber material, Temperature range RT + 20~ 400 ℃, liner size 450 × 450 × 450mm, with multi-stage programmable control, independent temperature limit alarm and fast and stable temperature control function, easy to clean and automatic operation.

$ 2052.00

The mirror stainless steel liner is easy to clean, Temperature resolution up to 0.1 ℃, supports multi-stage programmable control, can preset 7-stage 63-step program, and has an independent temperature limit alarm system to ensure safe operation.

$ 1222.00

32 infrared halogen heaters, temperature range RT + 5~ 350 ℃, can be set parabolic layer or rising slope, the maximum test plate size 570mm, support the intRoduction layer Linear dispersion simulation pRoduction process.

$ 108363.00

Using a roll-to-roll continuous solution cell process, the substrate is crystallized or attached under specific conditions. Equipped with a 130 ° C hot air Oven drying system, the effective application width is 180mm, and the mechanical speed range is 0.1-300 mm/min. The solution cell has a lifting function and a separate heating design to ensure process Stability and operation safety.

$ 48484.00

Temperature range 10~ 200 ℃, resolution of 0.1 ℃, hot air circulation system to improve Temperature uniformity, mirror stainless steel liner durable and easy to clean, support timing and over temperature protection function.

$ 493.00

Articles

Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
The heating film coater applies thick-film resistor paste onto the ceramic substrate.
The heating coating machine is used to apply thick film resistor paste on ceramic substrates. It reduces the viscosity of the paste through a heating platform and ensures uniform coating in conjunction with the coating head.
Vacuum adsorption coating table solves the problem of film substrate wrinkling.
The vacuum adsorption coating platform uses a microporous array connected to a vacuum system beneath the tabletop to create a pressure difference, tightly adsorbing the film substrate. This ensures it remains flat during the coating process, preventing wrinkles that could lead to uneven coating.
How to Utilize a Vacuum Adsorption Coating Machine to Solve the Slippage Issue During Coating on Flexible PET Substrates
The vacuum adsorption coating machine stabilizes the flexible PET substrate on the coating platform through negative pressure, effectively addressing the slipping issue during the coating process. Slipping is primarily caused by factors such as the smooth surface of PET, insufficient friction, and interference from coating pressure, which can lead to uneven coatings.
Effect of Platform Temperature on Surface Drying Time of Waterborne Polyurethane Coatings in Heated Automatic Film Applicators
This study investigates the influence of the platform temperature of a heated automatic film applicator on the surface drying time of waterborne polyurethane coatings. The experiments reveal that as the platform temperature increases, the surface drying time of the coating significantly decreases, showing a negative correlation between the two.
Vibration test bench simulates transport packaging environment testing.
Vibration testing tables simulate the vibration environment during transportation in the laboratory to test packaging and evaluate its protective performance. The tests primarily follow domestic and international standards, simulating sinusoidal or random vibrations that cover typical transportation conditions such as road and rail.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
Performance Comparison and Selection Guide Between Electric Vibration Tables and Hydraulic Vibration Tables
Electric shakers and hydraulic shakers are two commonly used vibration testing devices, each with different working principles. When selecting a model, factors such as test frequency, specimen weight, displacement requirements, and cost need to be considered.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Key Technical Points for Determining Paper Moisture Using the 105℃ Oven Method
This article introduces the specific procedure for measuring paper moisture using the 105°C oven method. The process involves placing paper samples into a 105°C oven and drying them until their weight remains constant, then calculating the moisture content based on the weight difference before and after drying.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.