Plating Thickness Gauge

Coating thickness gauges measure the thickness of coatings on substrate surfaces using magnetic induction, eddy current, or X-ray methods. They are used to detect the thickness of galvanized or chrome-plated layers on materials such as metals and plastics, and are applied for quality control in industries such as electroplating and automotive parts.
Selection
When selecting a coating thickness gauge, consider the substrate type (ferrous/non-ferrous), coating material, and thickness range. The magnetic induction method is suitable for steel substrates, the eddy current method for non-ferrous metals, and the X-ray method can measure various coating combinations. Choose between handheld or benchtop equipment based on measurement accuracy requirements and on-site environmental conditions.

Terms

Standards

Instruments

Lame plating movement rate 1-300mm/s, accuracy +/- 1%, support maximum 600 * 300mm substrate, can spray thickness 0.01~ 13mm, with 1L stainless steel pressure bucket, 5 inch touch screen control, energy consumption is only 100W.

$ 3623.00

Using reciprocating lame plating technology, the effective lame plating area of 160 × 80mm can be expanded to 200 × 100mm. Support 0.1-5 ml/min precision discharge control, with Vacuum chuck platform to ensure the substrate is flat. Integrated PLC and Touchscreen realize paraMeter preset and real-time monitoring.

$ 4108.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

The formed pRoduction process ensures stable structure, wet film thickness can be controlled to 100μm, chrome plating surface preparation improves Abrasion Resistance and ease of cleaning, and the effective application width reaches 500mm.

$ 231.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

The wet film thickness can be as low as 1.5 μm, the groove bottom is wider to provide greater Coating Weight, the chrome plating surface and extrusion process ensure durability and easy cleaning, avoiding the problem of traditional steel wire loosening.

$ 477.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Equipped with double spray guns to achieve uniform lame plating, the lifting range of the spray gun is adjustable from 10-500mm, the integrated air filtrate adjustment system supports magnetic or vacuum panel fixing, and improves the coating test Repeatability.

$ 67560.00

With lame plating and scraping dual functions, Spreader speed 0-5m/min, Spreader width 100-300mm, integrated automatic tension control and correction system, support 0-200mm lame plating height adjustment to ensure coating uniformity and ease of operation.

$ 19438.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

High Accuracy measurement in the full range, Probe with temperature compensation to ensure the accuracy of curved surfaces and small workpieces; IP64 Protection Rating, operating temperature -20 ℃ -70 ℃, three layers of shock protection; Adapted to iron-based non-iron-based Probe, storing 10000 readings.

$ 1230.00

The wet film thickness can be controlled to 1.5μm, the bottom of the groove is wider and the Coating Weight is larger, and the 304 stainless steel material and chrome-plated surface are used, which is durable and easy to clean, and avoids the problem of loose and broken wires.

$ 477.00

Measurement range 0.1~ 35μm, resolution 0.01μm, can measure more than 20 platings combinations such as Cr, Ni, Cu, etc., support single-layer and composite multi-layer measurement, equipped with 4 quick plating selection buttons to avoid misoperation.

$ 2010.00

With lame plating and scraping dual functions, coating speed 0-5m/min adjustable, equipped with UV light curing system, curing area 300 * 1000mm, support automatic tension control and deviation correction function.

$ 29120.00

Adopt bar Spreader and automatic lame plating method, coating speed 5~ 180mm/s, heating Temperature range RT +~ 200 ℃, support Vacuum chuck and automatic feeding function, ensure Spreader uniformity and Stability.

$ 8465.00

Articles

Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Selection of Coating Thickness Measurement Methods: Coulometry vs. Dissolution in Electrolytic Thickness Gauges.
This article compares two techniques in electrolytic thickness gauges: the coulometric method and the dissolution method. The coulometric method measures coating thickness through electrochemical dissolution, making it suitable for single-layer metal coatings with simple operation and high accuracy. The dissolution method, on the other hand, measures thickness via chemical dissolution, making it more appropriate for multilayer or complex coatings.