TDS Smart Water Quality Detector

The TDS intelligent water quality detector measures the total dissolved solids content in water through an electrical conductivity sensor. The instrument converts the electrical conductivity of water samples into TDS values, reflecting the concentration of inorganic salts and organic matter in the water. It is used for monitoring drinking water purity, reminding of water purifier filter replacement, and managing water quality in aquaculture.
Selection
When selecting, focus on the measurement range covering common water quality standards and ensuring precision meets daily monitoring needs. Check the electrode material for corrosion resistance, and consider temperature compensation functionality. Review the calibration methods and data storage capacity, and confirm that the power supply method matches the usage scenario. Pay attention to the protection level to suit the operating environment.

Terms

Instruments

With 5 measurement functions, support 1 to 5 point Conductivity Detector calibrating and automatic temperature compensation, can customize 13 paraMeters, equipped with 500 data storage and USB Communication interface, suitable for a variety of water quality paraMeters accurate measurement.

$ 667.00

With pH, conductivity, TDS and temperature Multi-ParaMeter measurement, pH range 0.0-14, EC range 0-3999 μS/cm, supports Automatic calibration and continuous monitoring, waterproof design and large screen display for easy operation.

$ 538.00

Measurement conductivity range 0uS~ 199uS, TDS range 0ppm~ 1999ppm, accuracy +/- 3%, with automatic temperature compensation and data retention function, easy to carry and use.

$ 117.00

Optical inspection Colorimetric detection principle, eliminate human error, measurement resolution of 0.1mg/L, Repeatability ≤ 2%, suitable for indoor and outdoor water quality testing environment.

$ 240.00

With +/- 3% F. S accuracy and +/- 1% Repeatability, support 0~ 1999ppm TDS Measurement range, high definition color screen display and automatic temperature compensation function, easy to carry and use.

$ 122.00

Can simultaneously measure 10 water quality indicators, IP67 waterproof design to adapt to harsh environments, built-in 45000 sets of data storage capacity, automatic identification of calibrating points to ensure Measurement accuracy.

$ 2247.00

Measurement range 2-3000uS/cm, Glass shell structure, three-core air interface, suitable for water quality analysis applications.

$ 114.00

Equipped with 7-inch TFT display, support conductivity, TDS, salinity, resistivity and Conductivity Detector ash 5 kinds of paraMeter measurement, Measurement accuracy of 0.5% F.S, automatic temperature compensation and 1000 groups Data storage function.

$ 593.00

Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.

$ 185.00

It can simultaneously measure 10 water quality paraMeters, IP67 waterproof level, 45000 sets of data storage capacity, automatic temperature compensation and Adjustment to ensure accurate and reliable measurement.

$ 2529.00

Combined ElectRode can simultaneously measure pH, conductivity, TDS, salinity and temperature, support one-button switching paraMeters; Conductivity Detector ElectRode platinum black to reduce Polarization effect, accuracy of +/- 0.01pH; with automatic temperature compensation and IP67 dustproof and waterproof design.

$ 213.00

With 12 water quality paraMeter detection capabilities, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and long-life Illuminant, support custom Linear dispersion calibrating and data smoothing.

$ 1058.00

With 4 measurement functions, support pH range -2.000~ 20.000 and conductivity 0~ 20mS/cm, automatic temperature compensation and ElectRode diagnosis, can store 500 sets of data and comply with GLP specifications.

$ 556.00

Measurement range pH 0.00-14, EC 0.00-20 mS/cm with automatic temperature compensation and stable reading lock function for easy operation.

$ 409.00

TDS value 7447ppm, capacity 480mL, PTFE bottle Encasement, versatility, suitable for daily solubility total solid calibrate, to ensure measurement accuracy.

$ 106.00

Articles

Wavelength selection for the determination of sulfate content in water quality using photometric titrator
This article discusses how to select the wavelength when using a photometric titrator to determine the sulfate content in water. The core issue lies in the fact that wavelength selection directly affects the accuracy and anti-interference capability of the detection.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
How to Choose a Suitable Multi-Parameter Water Quality Analyzer Based on Detection Indicators
When selecting a multi-parameter water quality analyzer, the first step is to clarify the parameters that need to be measured, such as physical, chemical, or biological indicators, because different parameters require different detection principles, measurement ranges, and accuracy levels for the instrument.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How can multi-parameter water quality analyzers avoid cross-contamination and improve data accuracy?
This article mainly discusses how to avoid cross-contamination in multi-parameter water quality testing to ensure data accuracy. Cross-contamination refers to the residue from a previous sample affecting the results of the next sample, which may lead to data deviation.
Which is more convenient for water hardness testing: the electrode method or the titration method?
Both electrode method and titration are used to measure water hardness. The choice depends on specific needs: opt for the electrode method for speed, and choose titration for accuracy.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.