Electric Constant-Temperature Bath

The electric constant temperature water bath maintains a constant temperature of the liquid inside the tank through electric heating and a temperature control system. It is used for constant temperature treatment of samples, reagent reactions, and instrument calibration, and is commonly found in laboratory physical property testing and chemical reaction processes.
Selection
When selecting, consider that the temperature range should cover experimental needs, temperature control accuracy should match sample requirements, bath capacity should accommodate container dimensions, material corrosion resistance should align with the liquid properties, stirring functionality should ensure uniform temperature, and safety features must include over-temperature protection and grounding design.

Terms

Standards

Instruments

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

Temperature range covers -40 to 100 ℃, Temperature Fluctuation accuracy to +/- 0.05 ℃, resolution up to 0.01 ℃, and supports internal and external double cycle mode to meet the needs of various experiments inside and outside the tank.

$ 1285.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 60 ℃ and no drift, rotary oscillation ensures uniform mixing of samples.

$ 740.00

Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0-300rpm adjustable, swing amplitude 20mm, to meet different experimental needs.

$ 932.00

Temperature range covers -10~ 100 ℃, Temperature Fluctuation is accurate to +/- 0.05 ℃, support internal and external double cycle mode, tank volume 6L, to meet the needs of various experiments inside and outside the tank.

$ 725.00

Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude 20mm to ensure uniform mixing, timing function 0~ 120min to meet different experimental needs.

$ 740.00

Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude of 20mm, to ensure the stability and reliability of the experimental process.

$ 740.00

Temperature range -5~ 100 ℃, Temperature Fluctuation Accurate to +/- 0.05 ℃, equipped with circulating pump to support internal and external dual circulation mode, can flexibly meet the temperature control needs of in-tank and out-of-tank experiments.

$ 774.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to meet the needs of complex experiments.

$ 12820.00

Temperature range -20~ 100 ℃, Temperature Fluctuation as low as +/- 0.05 ℃, support internal and external circulation, equipped with 6L/min circulating pump, to meet the precise temperature control of various experiments inside and outside the tank.

$ 830.00

Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0~ 300rpm adjustable, swing amplitude 20mm to ensure uniform mixing, timing function 0~ 120 minutes flexible setting.

$ 740.00

Articles

Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.