Industrial Ovens

Industrial ovens heat air through electric heating elements and use hot air circulation to ensure uniform temperature inside the chamber. They are used for processes such as material drying, curing, and heat treatment, and are employed in industries like coatings and plastics for product drying and performance testing.
Selection
Determine the temperature range and uniformity requirements based on material characteristics; select a model with matching capacity and power according to production output; consider special process requirements such as explosion-proof and corrosion resistance; compare the factors affecting energy consumption, such as insulation materials and air duct design; confirm that temperature control accuracy and safety protection functions meet operational standards.

Terms

Standards

Instruments

Impedance input controller, equipped with two-stage signal amplifier, Measurement accuracy of +/- 0.01pH, support for external brands of ElectRode, suitable for harsh industrial environments.

$ 211.00

With dual range and dual accuracy design, Capacity 30kg + 40kg, minimum weighing 0.1g + 0.5g, support dual mode of weight counting, six-stage shock-proof filtering and various unit conversions to meet the needs of complex industrial environments.

$ 532.00

Adopt industrial PID self-tuning control technology, temperature control accuracy +/- 2 ℃, the highest temperature up to 1000 ℃, with over-temperature protection and automatic thermostatic Timing function, Furnace volume 7L, heating uniform and stable.

$ 412.00

With dual range and double accuracy design, weighing range up to 20kg + 30kg, accuracy 0.1g + 0.2g, support six-level shock filtering and a variety of weighing modes, adapt to complex industrial environment.

$ 396.00

Adopting 7-inch Capacitive Touchscreen Control, Supports 2000W Maximum Power and Automatic Frequency Tracking, Supporting Sound Insulation Box Reduces Noise by More than 70%, Industrial Grade Titanium Amplifier Rod Can Work Continuously for More than 1 Hour.

$ 4898.00

Adopt industrial PID self-tuning temperature control technology, Temperature Fluctuation +/- 2 ℃, display accuracy 1 ℃. Up, down, left and right 4-sided heating structure, Furnace volume 30L, with over-temperature protection and automatic timing function.

$ 751.00

Using Industrial Sensor, Response Time T90 is less than 60 seconds, with waterproof, dustproof and explosion-proof function, round and durable shell, suitable for Gas detection in various industrial environments.

$ 248.00

Using 16-bit AD converter and K-type Thermocouple, sampling speed 16 times per second, Measurement range -50 ° C to 1300 ° C, support Fahrenheit switching and data retention functions.

$ 104.00

Accuracy up to 0.1g, metal casing to ensure durability, built-in automatic dual range and six-stage shock filter, support for a variety of weighing modes such as percentage and density direct reading, improve the ease of operation.

$ 319.00

With dual range 1.5kg + 3kg and dual accuracy 0.01g + 0.02g, it supports dual mode conversion of weight counting, built-in temperature display and adjustable six-level shock-proof filter to ensure stable and reliable weighing.

$ 325.00

With dual range double accuracy function, weighing range 50kg + 10kg, accuracy 0.5g + 0.1g, support weighing and counting dual mode, Automatic calibration and a variety of unit conversion, the structure is sturdy and durable.

$ 306.00

Accuracy up to 0.1g, with automatic dual range and six-stage shock filter adjustable function, support a variety of weighing modes such as percentage weighing and density direct reading to ensure fast and stable weighing.

$ 344.00

With double range and double accuracy function, Capacity 30kg, minimum reading 0.1g, support 20 kinds of unit conversion and a variety of weighing modes, the whole machine structure is sturdy and torsion resistant.

$ 306.00

Equipped with 8 measurement channels, accuracy up to +/- 1 ° C, built-in 20 batches of 50000 readings large memory, simplified operation through three keys, USB-C interface supports fast data transfer and charging, suitable for high temperature environment monitoring.

$ 6281.00

Infinity Optical inspection system and Modular function design can realize polarization and dark field observation; Coarse fretting coaxial focusing system fretting grid value of 2 μ m, guide column lifting device to adapt to different Film thickness workpiece detection needs.

$ 2252.00

Articles

Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Key Technical Points for Determining Paper Moisture Using the 105℃ Oven Method
This article introduces the specific procedure for measuring paper moisture using the 105°C oven method. The process involves placing paper samples into a 105°C oven and drying them until their weight remains constant, then calculating the moisture content based on the weight difference before and after drying.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Temperature gradient control in high-temperature ovens during thermal resistance testing.
The heat resistance test simulates the performance of materials under high temperatures using a high-temperature oven, and the accuracy of its results is highly dependent on the uniformity of temperature inside the oven. If the temperature gradient is poorly controlled, it can lead to uneven heating of samples from the same batch, compromising the validity of the test.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.
Natural Convection vs Forced Air Drying: What’s the Difference Between the Two "Schools" of Laboratory Ovens?
This article introduces two drying methods for laboratory ovens: natural convection and forced air drying. What are the differences between them?