Combustible Gas Monitor

Flammable gas monitors detect gas concentrations through catalytic combustion or infrared principles. When the sensor comes into contact with flammable gases, it generates changes in electrical signals, which are used for leak warnings in locations such as petrochemical plants and gas stations.
Selection
When selecting, consider matching the types of gases detected with the appropriate sensor types, ensure the explosion-proof rating meets environmental requirements, check the response time and calibration cycle, and confirm that the display method and alarm functions meet on-site needs.

Terms

Instruments

Using Semiconductor Sensor, Response Time T90 is less than 10 seconds, detecting a variety of combustible gases, range 0~ 50% LEL, with sound and light alarm and LED large screen display.

$ 141.00

It adopts flameproof structure design, supports 4-20mA, RS485 and switch output, Response Time ≤ 30 seconds, Detection error ≤ +/- 3% F.S. It can be operated by remote control without opening the lid, with sound and light alarm function, suitable for dangerous environment gas monitoring.

$ 254.00

Using semiconductor Sensor technology, the detection sensitivity can be adjusted to 50PPM methane, Response Time ≤ 1 second, Warm-Up Time is less than 110 seconds, support 9 hours of continuous work, with LED light alarm and low power indication function.

$ 99.00

Using infrared NDIR detection principle, range 0-5% Vol, Response Time ≤ 30 seconds, support 4-20mA, RS485 and switch output, with explosion-proof structure and remote monitoring capability.

$ 332.00

Can simultaneously detect four gases, Electrochemical sensor, Response Time instant, alarm sound up to 80 decibels, operation temperature range -10~ 50 ℃, portable design weighs only 360 grams.

$ 241.00

Using infrared NDIR detection principle, range 0-1000ppm, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output options, support remote data transmission and customized range.

$ 848.00

Using catalytic combustion principle to detect 0-100% LEL range, Response Time ≤ 30 seconds, support 4-20mA and RS485 output, with flameproof structure and remote alarm function.

$ 383.00

Using catalytic combustion detection principle, the range covers 0-100% LEL, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output, support remote monitoring and infrared remote control operation, through a number of international safety certifications.

$ 190.00

Using catalytic combustion principle to detect 0-100% LEL range, Response Time ≤ 30 seconds, with flameproof structure and multi-signal output, support remote monitoring and customized Sensor.

$ 202.00

Sensor imported to ensure high Sensitivity and stability, Response Time ≤ 15 seconds, with 6000 alarm record query function, providing sound and light vibration triple alarm and super high waterproof design.

$ 122.00

Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with infrared remote control debugging and 4~ 20mA output, support alarm record query and automatic temperature compensation, suitable for hazardous environment.

$ 152.00

Supports simultaneous detection of four gases and temperature Humidity, adopts dual temperature Humidity compensation design, has zero point automatic correction function, Protection Rating up to IP66, Operating temperature range -40~ 55 ℃.

$ 301.00

Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with automatic zero correction and temperature compensation functions, support 4~ 20mA output and infrared remote control debugging, suitable for dangerous areas 1 and 2 zones.

$ 143.00

Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with automatic zero correction and temperature compensation function, support 4~ 20mA and RS485 output, infrared remote control safety adjustment.

$ 122.00

Using catalytic combustion Sensor, range 0~ 100% LEL, with automatic zero correction and temperature compensation function, support infrared remote control adjustment and 4~ 20mA standard output, suitable for dangerous places 1 and 2 zones.

$ 135.00

Articles

Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Operating Specifications for the Determination of Hexavalent Chromium Content in Wastewater Using Colorimetric Titration Apparatus
This article introduces the standard operating procedure for determining hexavalent chromium content in wastewater using a colorimetric titrator. The method is based on the reaction between hexavalent chromium and diphenylcarbazide under acidic conditions to form a purplish-red complex, with the titration endpoint determined by monitoring changes in absorbance at a wavelength of 540 nanometers.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Principle and Application of Vacuum Decay Leak Testing Equipment
The vacuum decay leak tester is a non-destructive detection device that quantitatively detects leaks by monitoring minute pressure changes in the test chamber after vacuum evacuation.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
Drying Time Determination: Simultaneous Verification of Surface Drying Test Method, Through-Drying Test Method, and Instrumental Test Method
This article discusses three methods for determining the drying time of materials such as coatings. Traditional methods are divided into surface drying and through drying measurements, which are simple to operate but rely on subjective judgment. Instrumental methods provide objective data by monitoring physical changes such as mass and resistance, offering higher precision but at a higher cost.
How to Choose the Right Contact Angle Measuring Instrument Based on Sample Characteristics
Contact angle measurement is a key method for evaluating the wettability of solid surfaces and is widely used in fields such as materials science, coating industry, textile testing, electronic packaging, and environmental monitoring.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.